Nemco Food Equipment Hot Plates - Operations Manual User Manual
Nemco food equipment
![background image](/manuals/279459/1/background.png)
NEMCO FOOD EQUIPMENT
301 MEUSE ARGONNE, HICKSVILLE, OHIO 43526 PHONE (419) 542-7751
NEMCO Hot Plates
6310-1, 6310-2, 6310-3
6310-1-240, 6310-2-240, 6310-3-240
6311-1-240, 6311-2-240
INSTALLATION INSTRUCTIONS
To Unpack:
1.) Remove the top packing pieces.
2.) Lift unit out of box.
3.) Remove any outside packaging.
4.) Remove the internal packaging.
Initial Setup:
1.) Remove the plastic coating from all stainless steel surfaces.
2.) Install the adjustable legs into the pre-threaded holes in the base of the unit. Unit must be operated with the legs provided.
3.) Clean unit with mild detergent and water. Be sure to dry unit.
4.) CAUTION – To reduce the risk of fire, the appliance is to be installed in non-combustible surroundings only, with no
combustible material within 18 inches of the sides, front, or rear of the appliance or within 40 inches above the appliance.
The appliance is to be mounted on floors of noncombustible construction with non-combustible flooring and surface finish
and with no combustible material against the underside, or on noncombustible slabs or arches that have no combustible
material against the underside. Such construction shall in all cases extend not less than 12 inches beyond the equipment
on all sides.
Place the unit on a sturdy table or counter top and be sure it is out of reach form children.
“WARNING” During normal operation the exterior of the unit is HOT.
OPERATING INSTRUCTIONS
1.) Plug the unit into the appropriate power supply as indicated on the data plate.
2.) Adjust to desired temperature.
3.) After use, turn thermostat knob to off position.
Please Note: 120v models are not designed for saucepots over 4 quarts. They are designed for pan frying sautéing, or simmering.
MAINTENANCE AND CLEANING INSTRUCTIONS
Daily Cleaning:
1.) Unplug unit prior to cleaning.
2.) Clean unit with a mild detergent and warm water. Be sure to dry unit.
3.) Do not immerse in water.
Maintenance:
If unit fails to operate properly call NEMCO customer service at 1-800-782-6761
TROUBLESHOOTING
Won’t Heat
Check that unit is plugged in
Check that switch is turned to desired heat setting
Check receptacle for proper voltage
Product Cold/Not to Temperature
Adjust switch to increase temperature.
Product too Hot
Adjust switch to decrease temperature.
Unit Blows Fuse or Circuit Breaker
Check to make sure circuit is not overloaded.
Service Parts List
45380
Pilot Light 120V (6310-1, 6310-2, 6310-3)
45495
Foot (6311-1-240, 6311-2-240)
45781
Pilot Light 220V (all 220V models)
46376
Cord Grip (6310-1)
46751
Cord Set (6310-1)
46789
Switch (all models)
46927
Leg Adjustable ( 6310-1, 6310-2, 6310-3, 6310-1-240, 6310-2-240, 6310-3-240)
46931
Knob, Thermostat (All Models)
47402
Cord Grip (6310-2, 6310-3, 6310-1-240, 6310-2-240, 6310-3-240, 6311-1-240)
47405
Cord Grip (6311-2-240)
47416
Cord Set (6310-2, 6310-3)
47417
Cord Set 240V (6310-1-240, 6310-2-240, 6310-3-240, 6311-1-240)
47434
Cord Set (6311-2-240)
67101
Element 240V 1500W (6310-2-240, 6310-3-240, 6311-1-240, 6311-2-240)
67102
Element 240V 2000W & 120V 500W (6310-2, 6310-3, 6310-1-240, 6311-2-240)
67306 Element 120V 1500W (6310-1, 6310-2, 6310-3
46029