beautypg.com

Bearing and washer detail – Grain Systems Custom, Utility and Bulk Tank Augers PNEG-195 User Manual

Page 14

background image

4. Assembly

14

PNEG-195 4" Utility and Bulk Tank Auger

Bearing and Washer Detail

Figure 4A

Install supplied stub shaft inside auger flight with 1/4" x 1-1/2" bolt and a 1/4" lock nut. Position flight with
stub shaft and washer into unloader bearing.

(See Figure 4A.)

4" Unloaders require 17" of exposed flight. It is necessary to field cut auger tube lengths to accommodate
required exposure. Butt the auger tube to the unloader tube and attach using a connecting band.

IMPORTANT: Auger stub shaft supplied is designed to fit GSI 4" bulk tank augers. If using a

different auger supplier it may be necessary to modify or fabricate a stub shaft for
the unloader bearing.