Grain Systems Bin Accessories PNEG-1867 User Manual
Page 11
2. Inverted “T” Foundation 4" Outside Stiffened (CFL Series) Commercial Farm Tanks
PNEG-1867 Concrete Foundation Recommendations for GSI CFL Grain Bins
11
Diameter of Bin: 54'
Soil Bearing Capacity: 3000 PSF
Ring #
8
10
11
13
14
16
17
A
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-0"
1'-1"
B
2'-9"
3'-5"
4'-3"
5'-1"
6'-0"
6'-9"
7'-8"
C
27'-10"
27'-10"
27'-10"
27'-10"
27'-10"
27'-10"
27'-10"
D
28'-2"
28'-6"
28'-10"
29'-2"
29'-6"
29'-10"
30'-2"
M
5 #4's
6 #4's
6 #4's
7 #4's
7 #4's
5 #5's
5 #5's
N
3 #5's
4 #5's
4 #5's
5 #5's
6 #5's
6 #5's
7 #5's
P
#5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c #5 @ 13" c/c #6 @ 13" c/c
#6 @ 9" c/c
Rerod
#4 (ft.)
6500
6900
6900
7200
7200
4800
4800
#5 (ft.)
900
1200
1300
1600
2000
2800
3100
#6 (ft.)
0
0
0
0
0
1100
1700
Cu. Yds.
Concrete
Footing
18
23
28
33
38
43
52
Wall
33
33
33
33
33
33
33
Floor
42
42
42
42
42
42
42
Total
93
98
103
108
113
118
127
Diameter of Bin: 60'
Soil Bearing Capacity: 3000 PSF
Ring #
12
14
16
18
A
1'-0"
1'-0"
1'-0"
1'-0"
B
4'-7"
6'-0"
7'-1"
8'-5"
C
30'-9"
30'-9"
30'-9"
30'-9"
D
32'-3"
32'-8"
33'-4"
33'-11"
M
5 #5's
6 #5's
7 #5's
5 #6's
N
5 #5's
6 #5's
7 #5's
9 #5's
P
#5 @ 14" c/c
#5 @ 11" c/c
#6 @ 9" c/c
#6 @ 6" c/c
Rerod
#4 (ft.)
5700
5900
5900
5900
#5 (ft.)
3600
4700
4100
1800
#6 (ft.)
0
0
1700
5000
#7 (ft.)
0
0
0
0
Cu. Yds.
Concrete
Footing
32
42
50
64
Wall
36
36
36
36
Floor
51
51
51
51
Total
119
129
139
151