Chapter 6: stiffeners – Grain Systems Tanks PNEG-4090A User Manual
Page 60
Base Stiffener (10–16 Ga) to a Base Boot Connection
Reference the following information when connecting a base stiffener (CTS-2123XX) to a base boot (CTS-
2121XX).
Figure 6-23 Base Stiffener (10–16 Ga) to a Base Boot Connection
A
Base stiffener (CTS-2123XX)
B
Base boot (CTS-2121XX)
C
3/8 x 1 Bolt (S-7485)
D
3/8 Nut (S-9426)
E
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
Close-Punch Connection for a Base Stiffener (10–16 Ga) to a Base
Boot
Reference the following information for a close-punch connection for a base stiffener (CTS-2115XX) to a
base boot (CTS-2121XX).
Figure 6-24 Base Stiffener (10–16 Ga) to a Base Boot Close-Punch Connection
A
Close-punch base stiffener (CTS-2115XX)
B
Close-punch base boot (CTS-2121XX)
C
3/8 x 1 Bolt (S-7485)
D
3/8 Nut (S-9426)
E
Completed assembly
NOTE: Two-post stiffeners shown. The bolt pattern will
vary for three-post. Only place bolts where
holes in the stiffeners align with holes in the
sidewall sheet.
60
Pneg-4090A 90 Ft Diameter 40-Series Bin