SIGNAL LEVEL METER
FREQUENCY
Tuning Range: 5 to 872 MHz.
Tuning Resolution: 125 KHz.
IF Bandwidth: 280 KHz.
POWER RANGE
Analog Channels: -30 to +60 dBmV
Digital Channels: -23 to +67 dBmV
ACCURACY
Typical: +/- 0.5 dB
Max Additional Error at 70° F: +/- 0.5 dB
Max Additional Error from 0° to 120° F: +/- 1.0 dB
Digital Channel Error: additional +/- 0.5 dB
LEAKAGE DETECTOR (CLI OPTION)
FREQUENCY
Tuning Range: 108 to 140 MHz.
Tuning Resolution: 25 KHz.
IF Bandwidth: 280 KHz.
SENSITIVITY
2 uV/m (with duck antenna, 3ft. from leak)
ACCURACY
Typical: +/- 0.5 dB
Max Additional Error at 70° F: +/- 0.5 dB
Max Additional Error from 0° to 120° F: +/- 1.0 dB
FEATURES
-Audio warble identifies tagged channels
-Variable pitch aids peaking
-Video filter rejects false leaks
INGRESS DETECTOR
FREQUENCY
Tuning Range: 5 to 40 MHz.
Tuning Resolution: 250 KHz.
IF Bandwidth: 280 KHz.
POWER RANGE
-35 to +60 dBmV
ACCURACY
Typical: +/- 0.5 dB
Max Additional Error at 70° F: +/- 0.5 dB
Max Additional Error from 0° to 120° F: +/- 1.0 dB
CARRIER TO NOISE (C/N)
Range: 50 dB
Minimum Carrier Level: +10 dBmV
Accuracy: +/- 2 dB at 70° F; +/- 3 dB from 0° to 120° F
Measurement made on active analog channels
HUM
Range: 0 to 5%
Filter: 20 to 200 Hz.
Measurement made on active analog channels
BATTERY
Type: 6 high-capacity sub-C NiCad cells
Charge Time: 4 hrs.
Run Time: 4 hrs. continuous
Electronic Shut-Off: Saves power
GENERAL
Dimensions: 4.25”h x 10”h x 2.75”h (11cm x 25.5cm x 7cm)
Weight: 4.25 Lbs (1.9 Kg) including case & battery
STANDARD CHANNEL PLANS
NTSC (EIA), HRC, IRC, AIR (VHF/UHF) and PAL
Custom plans available on request
MEASUREMENT MODES (13)
Single Analog Channel, Single Digital Channel, Single
Frequency, 15 Channel Zoom, Sub-Band Channels, Full
Scan (135 Channels), Favorite Channels (9 Channels),
Tilt, Ingress, Leakage (800CLI only), C/N, HUM, 24Hr Scan
and Auto-Check (available on multi-channel modes)
ACCESSORIES SUPPLIED
Padded Nylon Case: CASE05
110 Volt AC Charger: T70
12 Volt Car Charger: CH04
NiCad Battery Pack: BAT07
Operator’s Manual: ST1008
OPTIONAL ACCESSORIES
Strand Hook: SH02
PC Download Cable: CA20
220/240 Volt AC Charger: T70E
Rubber Duck Antenna: ANT01 (CLI option)
Dipole Antenna: ANT02 (CLI option)
Mag. Mount Monopole Antenna: ANT03 (CLI option)
Sadelco DisplayMax 800 / 800CLI Signal Level Meter Specifications
SINGLE DIGITAL CHANNEL
SINGLE ANALOG CHANNEL
FULL SCAN & CHECK
MEASURE INGRESS
ZOOM - 15 CHANNELS
FAVORITE CHANNELS
Quickly tune and display
the average power of a
single digital channel.
The spectrum analyzer
display shows how the
power is distributed over
channel’s bandwidth.
Quickly tune and display
the picture carrier, audio
carrier and dB difference
on a single screen.
Monitor audio quality on
the built-in speaker.
View the response of the
entire system including
both analog and digital
channels. Press the
‘check’ key for an on-
screen pass/fail summa-
ry of the system.
Check for ingress on the
return-path. The spec-
trum analyzer display
reveals the ingress sig-
nals that interfere with
digital services such as
VoIP and high-speed
data.
View the response of 15
consecutive channels.
Provides better detail
than the Full Scan
mode. Press the ‘check’
key for an on-screen
pass/fail summary.
View only ‘Favorite’
channels for a quick
snap-shot of the system.
Press the ‘check’ key for
an on-screen pass/fail
summary.