Velleman DVM893 User Manual
Page 15

DVM893
V. 03 – 01/02/2013
15
©Velleman nv
maximum display
1999
LCD display size
31 x 61 mm
ranging mode
manual
over range indication
yes, “1”
low battery indication
yes,
polarity indication
“–” displayed automatically
data hold
yes
automatic power-off
yes
power supply
9 V battery
dimensions
190 x 89 x 51 mm
weight
± 412 g (including battery)
accessories
user manual / test leads / holster / battery / K-type
thermocouple (250 °C) / multifunctional test socket
9.1 Accuracy
Accuracy: ± (% reading + digits) with one year of warranty.
Reference conditions: ambient temperature from 18 °C to 28 °C, relative humidity
< 80 %.
DC voltage
Range Resolution
Accuracy
200 mV
0.1 mV
± (0.5 % of reading + 2 digits)
2 V
1 mV
20 V
10 mV
200 V
100 mV
1000 V
1 V
± (0.8 % of reading + 2 digits)
Input impedance: 10 MΩ
Max. input voltage: 1000 VDC or 750 VAC rms; 250 VDC or 250 VAC rms for
200 mV measurement range.
AC voltage
Range Resolution
Accuracy
2 V
1 mV
± (0.8 % of reading + 3 digits)
20 V
10 mV
200 V
100 mV
750 V
1 V
± (1.2 % of reading + 3 digits)
Input impedance: 10 MΩ
Max. input voltage: 1000 VDC or 750 VAC rms; 250 VDC or 250 VAC rms for
200 mV measurement range.
Frequency response: 40 Hz to 400 Hz sine wave rms (average response).
Frequency response is 200 Hz for 750 V.
DC current
Range Resolution
Accuracy
2 mA
1 µA
± (0.8 % of reading + 1 digits)
20 mA
10 µA