DVM8810

VELLEMAN

3

DVM8810 – INFRARED THERMOMETER

1.

Features & Applications

To all residents of the European Union

Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized

company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

precise measurements without actual contact with the target

built-in laser pointer

switchable temperature units (°C/°F)

automatic data-hold and automatic power off functions

the device measures the temperature of an object with a 1” diameter from a distance of 8”

backlit LCD display


This device has various applications: food preparation, safety inspection, screen printing, etc.

2.

Safety


Do not point the beam at the human eye or at the eyes of animals.

Do not aim the beam at reflective surfaces as the reflected beam might hit one of your eyes.

Do not use the device in proximity of explosive gases.

3.

General Specifications


Display

: 3 ½-digit LCD (1999 counts) with backlighting

Measuring Range

: -20°C to +270°C / -4°F to +518°F

Sampling Rate

:

±

1 reading/sec

Spectral Response

: 6-14um

Power Off

: automatic deactivation after 7 seconds

Operating Temperature

: 0 to 50°C / 32 to 122°F

Operating Relative Humidity

: max. 80% RH

Power Supply

: 9V-battery

Fig. 1

Class II laser diode. Do not stare into beam.
Wavelength: 650685nm. Max. output power: < 1mW.
EN 60825-1:1994+A2:2001+A1:2002