6. Connect the wiring [1] to the terminals according to the diagram
on page 2. Wire colours:
x red (+)
y black (-)
z brown
Warning: do not short-circuit any terminals.
7. Connect the power supply.
8. To test the PIR sensor, set the light sensitivity to OFF and the
movement sensitivity and 5” to ON. The load should switch on
immediately and – when no movement is detected – switch off
after 5 s.
Note: DO NOT change the DIP switch settings when power is
connected!
5. Technical Spe cifications
switch type
relay
detection angle
100°
detection range
8 m (@ 22 °C)
rated load
25 W resistive load
(max. inrush current 2.1A)
input
12 Vdc, 2.6 A
output
max. 12 Vdc 2.5 A / 25 W
working temperature -10 °C to +40 °C
working humidity
< 93 % RH
time-delay switch
5 s, 30 s, 1 min, 3 min, 5 min, 8 min
light control
< 3 lx to 2000 lx
dimensions
visible part
Ø 22 x 10 mm
hidden part (controller) 55 x 25 x 35 mm
weight
± 41 g