4. Wiring
• Earthing
The ground wire should be connected to the module frame or, better, to one of the
M6 fixing screws (see fig.).
5. Technical Specifications
SOL15
SOL16
max. power
15W ± 5%
40W
open circuit voltage (V
oc
)
21 ~ 23V
61V
max. working voltage (V
mp
) 17.5V
46V
max. working current (I
mp
) 850mA 870mA
cable length
± 1.8m
±1m
operation temperature
-40°C ~ 85°C
-40°C ~ 85°C
storage temperature
-40°C ~ 85°C
-40°C ~ 85°C
dimensions
923 x 313 x 22mm
643 x 1253 x 37mm
weight 4.9kg
14.7kg
extension cable (not incl.)
SOL/SPC1
SOL/SPC2
optional voltage controllers (not incl.)
SOL4UCN2
SOL7UC
SOL30UC12V
(*)
SOL30UC24V
* use a SOL30UC24V when installing two SOL15s in series
Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or
injury resulted from (incorrect) use of this device.
For more info concerning this product, please visit our website www.velleman.eu.