nv
Problem: charge indicator [1] is continuously on.
Reason: battery is charging.
Possible solutions: this is a normal operating condition.
Problem: charge indicator [1] is blinking.
Reason: battery is trickle-charging.
Possible solutions: this is a normal operating condition when battery is fully charged.
Problem: charge indicator [1] is off.
Reason: no power from solar panels.
Possible solutions:
• This is a normal condition during night time when the solar panel doesn’t receive any
sunlight
• When it happens during day-time, carefully check all connections and make sure they
are all secured tightly.
9.
Technical Specification
rated voltage
12Vdc / 24Vdc (auto-detection)
load current (max.)
30A
overvoltage protection
20Vdc / 40Vdc
over-charge protection
13.7V/27.4V (default value, can be reset)
over-discharge protection
10.5V/21V (default value, can be reset)
temperature compensation
-3mv/°C/cell
no load loss
max.20mA
max. cable section
6mm²
operating temperature
-25°C - 55°C
solar panel input voltage
12V system max.20V/24V system max.40V
dimensions 162x110x50mm
weight 371g
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use of this
device.
For more info concerning this product and the latest version of this user manual,
please visit our website
www.velleman.eu
.
The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman
nv. All worldwide rights reserved. No part of this manual may be copied, reproduced,
translated or reduced to any electronic medium or otherwise without the prior written
consent of the copyright holder.