3. Technical Specifications


Working Voltage

12VDC via reversing light

Rated Current

12mA ~ 120mA

Detection Range / Angle

0.3m ~ 1.5m / H > 60°, V > 60°

Working Temperature

-20°C ~ 70°C

Dimensions

Control Unit

85 x 45 x 25mm

Sensor

Ø 25 x 21mm

Buzzer

60 x 42 x 16mm

Weight 279g

How To Interpret the Alarm Sounds

Stage Distance

Awareness

Alarm Sound

1

150 ~ 100cm

Safe

bi - - - - - bi - - - - - bi

2

90 ~ 50cm

Alarm

bi - - - bi - - - bi

3

40 ~ 30cm

Alarm

bi - bi - bi

4

0 ~ 20cm

Danger

bi- - - - - - - - - - - - - -

4. Connection Diagram


• Connect the buzzer to the ALM output. There is only one way to insert the plug. Do not force.

• Connect the power cable to the PWR input. There is only one way to insert the plug. Do not force. Connect the black cable (-)

to the mass of the vehicle (usually the chassis). Connect the +12VDC red cable (+) to the reverse light.

• Connect each sensor to either one of the A, B, C or D inputs. There is only one way to insert the plug. Do not force.