• Unscrew the top of the detergent injector and fill the injector with detergent.

• Screw the top back on.

• Remove the lance from the gun.

• Attach the detergent injector to the gun (fig. B7).

• Apply detergent so it thoroughly covers cleaning surface. Apply from bottom to top to prevent detergent from

sliding down and streaking.

• Allow detergent to remain on the surface for a few minutes. This is a good time to use a brush to lightly scrub

heavily soiled areas. Never allow detergent to dry on the cleaning surface.

• Remove the detergent injector from the gun.

• Rinse detergent from surface.

Remember to rinse the detergent injector with water after use!
Final Rinse
Start from the bottom up and make sure all detergent is removed from the target surface.
Shut-Down
• Make sure all detergent is flushed from the system.

• Turn off the motor.

• Turn off the water supply.

• Now trigger the gun to depressurise the system.

• Always wipe every surface of the pressure cleaner with a clean, damp cloth after use.

CAUTION: NEVER turn the water supply off before turning the motor off as this could seriously damage the

pump and/or the motor.

WARNING: NEVER disconnect the high-pressure discharge hose from the machine while the system is

pressurised. To depressurise: turn off the motor and then the water supply and squeeze the

trigger 2 to 3 times.

7. Tips to Prolong the Life of your High-Pressure Cleaner

• NEVER store the pressure cleaner outdoors or where it could freeze. This would seriously damage the pump.

• Never operate the unit without water.

• The pressure cleaner is not meant to pump hot water. NEVER connect it to a hot water supply as it will

significantly reduce the life of the pump.

• NEVER allow the unit to run for more than one (1) minute without spraying water. The resulting heat build-up

will damage pump.

8. Troubleshooting

Symptom

Possible Cause

Corrective Action

Unit doesn’t start

Unit is pressurised

Squeeze trigger on gun

Plug is not well connected or

electric socket is faulty

Check plug, socket and fuse

Extension cord too long or wire

size too small

Remove extension cord

Mains voltage supply too low

Check that main supply voltage age is

adequate

Pump doesn’t reach necessary

pressure

Water inlet filter is clogged

Clean water inlet filter

Pump sucking air from hose

connections

Check that connections and locking ring are

properly tightened

Nozzle worn or wrong size

Contact your dealer

Unloader clogged or worn

Contact your dealer

Valves clogged or worn

Contact your dealer

Fluctuating pressure

Pump sucking in air

Check that hoses and connections are tight

Clogged nozzle

Clean with tip cleaner (see higher)

Valves dirty, worn or stuck

Contact your dealer

Water seals worn

Contact your dealer

Motor stops suddenly

Extension cord too long or wire

size too small

Remove extension cord

No detergent suction (units with

attachable injectors)

Detergent injector clogged Clean

injector with warm water

Replace

injector

Unit starts to smoke

Overheated, overloaded or

damaged motor

Switch the unit off and contact your dealer

9. Technical Specifications

working pressure / max. pressure

70 bar (1000 psi) / 105 bar

flow 5

L/min

power 1400

W

working voltage

230 VAC/50 Hz

dimensions

390 x 270 x 260mm

weight 6

kg