beautypg.com

2 parameter adjustment - quick setup – VEGA VEGABAR 83 Profibus PA - Quick setup guide User Manual

Page 13

background image

13

5 Set up with the display and adjustment module

VEGABAR 83 • Profibus PA

46316-EN-131125

1

2

Fig. 9: Insertion of the display and adjustment module into the double chamber

housing
1 In the electronics compartment

2 In the connection compartment (with Ex-d-ia version not possible)

Note:

If you intend to retrofit the instrument with a display and adjustment

module for continuous measured value indication, a higher cover with

an inspection glass is required.

5.2 Parameter adjustment - Quick setup

To quickly and easily adapt the sensor to the application, select

the menu item "Quick setup" in the start graphic on the display and

adjustment module.

Carry out the following steps in the below sequence.
You can find "Extended adjustment" in the next sub-chapter.
1. Sensor address

In the first menu item you have to enter a sensor address. The selec-

tion switches on the electronics module are preset to sensor address

126. This means that the sensor address can be changed via the

display and adjustment module.

Quick setup - Presettings