VEGA VEGATOR 636 Ex User Manual
Page 26
26
9 Supplement
VEGATOR 636 Ex • Signal conditioning instrument
45508-EN-130627
Inverse current (I
0
)
< 10 µA
Adjustment elements
DIL switch block
for preadjustment of the switching delay and mode
Test key
for function test
Control lamps in the front plate
Ʋ Status indication operating voltage
LED green
Ʋ Status indication fault signal
LED red
Ʋ Status indication switching point
control
LED yellow
Ambient conditions
Ambient temperature
-20 … +60 °C (-4 … +140 °F), the permissible ambi-
ent temperature reduces linear from 60 °C (140 °F)
auf 40 °C (104 °F) with an operating voltage of
60 … 72 V DC
Storage and transport temperature
-40 … +70 °C (-40 … +158 °F)
Electrical protective measures
Protection rating
Ʋ Signal conditioning instrument
IP 30
Ʋ Terminal socket
IP 20
Overvoltage category
II
Protection class
II
Electrical separating measures
reliable separation (VDE 0106, part 1) between power
supply, sensor input, level relay and transistor output
Functional safety (SIL)
The instrument can be used in safety-instrumented systems according to IEC 61508/IEC 61511-1
(service proven).
If the instrument is already ordered with SIL qualification Ex factory, then the corresponding Safety
Manual with information on the topic "Functional safety (SIL)" is part of the shipment.
If the instrument is ordered Ex factory without SIL qualification, then the corresponding Safety
Manual is available under "www.vega.com", "Downloads", "Approvals".
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"
and "serial number search" as well as via "Downloads" and "Approvals".