beautypg.com

VEGA VEGATOR 636 Ex User Manual

Page 26

background image

26

9 Supplement

VEGATOR 636 Ex • Signal conditioning instrument

45508-EN-130627

Inverse current (I

0

)

< 10 µA

Adjustment elements
DIL switch block

for preadjustment of the switching delay and mode

Test key

for function test

Control lamps in the front plate

Ʋ Status indication operating voltage

LED green

Ʋ Status indication fault signal

LED red

Ʋ Status indication switching point

control

LED yellow

Ambient conditions
Ambient temperature

-20 … +60 °C (-4 … +140 °F), the permissible ambi-

ent temperature reduces linear from 60 °C (140 °F)

auf 40 °C (104 °F) with an operating voltage of

60 … 72 V DC

Storage and transport temperature

-40 … +70 °C (-40 … +158 °F)

Electrical protective measures
Protection rating

Ʋ Signal conditioning instrument

IP 30

Ʋ Terminal socket

IP 20

Overvoltage category

II

Protection class

II

Electrical separating measures

reliable separation (VDE 0106, part 1) between power

supply, sensor input, level relay and transistor output

Functional safety (SIL)
The instrument can be used in safety-instrumented systems according to IEC 61508/IEC 61511-1

(service proven).
If the instrument is already ordered with SIL qualification Ex factory, then the corresponding Safety

Manual with information on the topic "Functional safety (SIL)" is part of the shipment.
If the instrument is ordered Ex factory without SIL qualification, then the corresponding Safety

Manual is available under "www.vega.com", "Downloads", "Approvals".
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully

noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"

and "serial number search" as well as via "Downloads" and "Approvals".