beautypg.com

2 mounting, in general, 1 suitable housing versions, 2 installation on deck with protective cover – VEGA VEGAPULS 63 Ship-building User Manual

Page 5: Ab c

background image

5

2 Mounting, in general

VEGAPULS 63 • Cargo tank

45562-EN-130626

2 Mounting, in general

2.1 Suitable housing versions

A

B

C

Fig. 2: Areas on a ship - side view
A On deck

B Below deck

C Engine room

Plastic housing

Aluminium housing Stainless steel

housing (precision

casting)

On deck No

No

Yes

Below

deck

Yes

No

Yes

Engine

room

Yes

No

Yes

Tab. 1: Suitable housings for different areas of the ship

2.2 Installation on deck with protective cover

Housing

Protective cover

closed

Protective cover

vented

Plastic

Aluminium die-

casting

Stainless steel

housing 316L

(IP 68, 0.2 bar)

Cable gland for cable diameters of 7 … 12 mm. An additional seal for

cable diameters of 10 … 14 mm is attached.