beautypg.com

2 mounting, 2mounting – VEGA KV 31 Mounting brackets For tubes with ø 200…400 mm (Horizontal sensor mounting) User Manual

Page 5

background image

2

Mounting

Take note of the operating instructions of the corresponding sensor
MINITRAC and the source holder VEGASOURCE.

Take note of the following mounting instructions:

l

Mount the bracket first, then the sensor and the source container

l

The arrow cutout in the clamp (source container side) and the
transport lug of the source container must point in the same
direction (A) after mounting

l

Make sure that the two clamps (5 and 8) of the bracket are in
parallel. Do this by measuring the lateral distances between the
clamps

l

To avoid injuries, shorten the threaded rods (1) of the brackets to a
suitable length after mounting

Mount the bracket according to the following assembly drawing:

7

6

7

6

5

3

8 1

A

4

2

Fig. 3: Mounting bracket with horizontally mounted sensor

1

Threaded rod M10 x 620 mm (M10 x 42.41 in) - 4 pcs.

2

Hexagon nut M16 - 4 pcs.

3

Hexagon nut M10 - 16 pcs.

4

Washer for M16 - 4 pieces

5

Clamp - Source holder side (VEGASOURCE 31) - 1 piece

6

Washer for M10 - 8 pieces

7

Hexagon screw M8 - 2 pieces

8

Clamp - Sensor side (MINITRAC) - 1 piece

A

Arrow cutout of the clamp and the lug point in the same direction

Operating instructions

Mounting brackets for
horizontal mounting

Horizontal sensor
mounting

Mounting brackets KV 31 • Source holder SE

5

2 Mounting

41407

-

EN

-120228