VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) standpipe ver. 4 … 20 mA_HART - two-wire User Manual
Page 51
51
11 Supplement
VEGAPULS 62 standpipe version • 4 … 20 mA/HART - two-wire
36507-EN-121011
Seal
Antenna impedance
cone
Process temperature (measured on the process
fitting)
FFKM (Kalrez 6375)
PFFE
-20 … +200 °C (-4 … +392 °F)
FFKM (Kalrez 2035)
PFFE
-15 … +200 °C (5 … +392 °F)
FFKM (Kalrez 6230)
PFFE
-15 … +200 °C (5 … +392 °F)
Vessel pressure relating to the antenna
system
-1 … 40 bar/-100 … 4000 kPa (-14.5 … 580 psi)
Vessel pressure relating to the flange
nominal stage
see supplementary instructions manual "Flanges ac-
cording to DIN-EN-ASME-JIS"
Vibration resistance
1 g at 5 … 200 Hz according to EN60068-2-6 (vibration
with resonance)
Shock resistance
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable gland
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Ʋ Closing cap
M20 x 1.5; ½ NPT
Plug options
Ʋ Signal circuit
M12 x 1, according to ISO 4400, Harting HAN, 7/8" FF
Ʋ Indication circuit
M12 x 1
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, cord
0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve
0.2 … 1.5 mm² (AWG 24 … 16)
Electromechanical data - version IP 66/IP 68 (1 bar)
Options of the cable entry
Ʋ Cable gland with integrated connec-
tion cable
M20 x 1.5 (cable: ø 5 … 9 mm)
Ʋ Cable entry
½ NPT
Ʋ Blind stopper
M20 x 1.5; ½ NPT
Connection cable
Ʋ Wire cross-section
0.5 mm² (AWG 20)
Ʋ Wire resistance
< 0.036 Ω/m
Ʋ Tensile strength
< 1200 N (270 lbf)
Ʋ Standard length
5 m (16.4 ft)
Ʋ Max. length
180 m (590.6 ft)
Ʋ Min. bending radius
25 mm (0.984 in) with 25 °C (77 °F)
Ʋ Diameter approx.
8 mm (0.315 in)
Ʋ Colour - Non-Ex version
Blue
Ʋ Colour - Ex-version
Blue