51

10 Supplement

VEGABAR 53 • Profibus PA

36723-EN-130321

Ʋ Version IP 66/IP 68 (1 bar), connec-

tion cable PE

-20 … +60 °C (-4 … +140 °F)

Process conditions
The specifications of the pressure stage and product temperature are used as an overview. The

specifications on the type label are applicable.
Pressure stage, process fitting

Ʋ Thread 316L, depending on connec-

tion

PN 60, PN 600, PN 1000

Ʋ Hygienic fittings 316L, depending on

connection

PN 6, PN 10, PN 25, PN 40 (PN 40 only with DRD and

DIN 11851)

Ʋ Flange 316L

PN 16/PN 40 or 150 lb/300 lb

Product temperature, depending on the sealing

13)

Ʋ Without sealing (with process fitting

according to EN 837)

-40 … +105 °C (-40 … +221 °F)

Ʋ FKM (VP2/A)

-20 … +105 °C (-4 … +221 °F)

Ʋ EPDM (A+P 75.5/KW75F)

-40 … +105 °C (-40 … +221 °F)

Ʋ NBR (COG)

-20 … +105 °C (-4 … +221 °F)

Product temperature threaded fitting M44 x 1.25 as well as hygienic fittings, dependent on the seal-

ing

14)15)

Ʋ Without sealing

-30 … +150 °C (-22 … +302 °F)

Ʋ FKM (VP2/A)

-20 … +150 °C (-4 … +302 °F)

Ʋ EPDM (A+P 75.5/KW75F)

-30 … +150 °C (-22 … +302 °F)

Ʋ NBR (COG)

-20 … +150 °C (-4 … +302 °F)

Vibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

16)

Vibration resistance - Version with double

chamber housing of stainless steel

mechanical vibrations with 2 g and 5 … 100 Hz

17)

Vibration resistance - Versions up to

+150 °C (+302 °F)

mechanical vibrations with 0.7 g and 5 … 100 Hz

18)

Shock resistance

Acceleration 100 g/6 ms

19)

Electromechanical data - version IP 66/IP 67
Cable entry/plug

20)

13)

Version for oxygen applications up to 60 °C (140 °F).

14)

Hygienic fitting LA/LB up to +105 °C (+221 °F)

15)

Version for oxygen applications up to +60 °C (+140 °F).

16)

Tested according to the guidelines of German Lloyd, GL directive 2.

17)

Tested according to the guidelines of German Lloyd, GL directive 2.

18)

Tested according to the guidelines of German Lloyd, GL directive 2.

19)

Tested according to EN 60068-2-27.

20)

Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.