beautypg.com

7 mounting steps, external housing – VEGA VEGABAR 67 4 … 20 mA_HART User Manual

Page 18

background image

18

4 Mounting

VEGABAR 67 • 4 ... 20 mA/HART

36742-EN-130321

2. Insert the transmitter with connection tube or suspension cable

into the opening of the mounting bracket and counter nut

3. Fasten counter nut with SW 46 on the thread
Removal is carried out in reverse order.

4.7 Mounting steps, external housing

1. Mark the holes according to the following drilling template
2. Depending on the mounting surface, fasten the wall mounting

plate with 4 screws

90 mm (3.54")

R 3,5 mm

(0.14")

3mm

(0.12")

70 mm (2.76")

8 mm

(0.32")

93 mm (3.66"

)

110 mm (4.33"

)

Fig. 11: Drilling template - wall mounting plate

Tip:

Mount the wall mounting plate so that the cable entry of the socket

housing points downward. The socket housing can be displaced by

180° to the wall mounting plate.

Warning:

The four screws of the socket housing must only be hand screwed. A

torque > 5 Nm (3.688 lbf ft) can damage the wall mounting plate.

Wall mounting