beautypg.com

3 wiring plan, double chamber housing – VEGA VEGAPULS 67 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - four-wire User Manual

Page 28

background image

28

5 Connecting to power supply

VEGAPULS 67 • 4 … 20 mA/HART - four-wire

36532-EN-121011

5.3 Wiring plan, double chamber housing

The following illustrations apply to the non-Ex as well as to the Ex-d

version.

5 6 7 8

4...20mA

2

1

2

+

( )

(-)

1

Fig. 27: Electronics compartment, double chamber housing
1 Internal connection to the connection compartment

2 For indicating and adjustment module or interface adapter

Information:

The connection of an external indicating and adjustment unit is not

possible with this double chamber housing.

power supply

4...20mA

active

passive

common

IS GND

5

1

/L

/N

PE

2

+

( )

(-)

6 7

8

Fig. 28: Connection compartment with double chamber housing with mains

voltage

Terminal

Function

Polarity

1

Voltage supply

+/L

2

Voltage supply

-/N

5

4 … 20 mA output (active)

+

6

4 … 20 mA output (passive)

+

7

Mass - output

-

8

Function ground with installa-

tion according to CSA

Electronics compartment

Connection compartment

with mains voltage