L

0

10 mm (0.394

")

-10 mm (-0.394

")

0,1 m (3.937

"

)

0,15 m

(5.906

")

1

1

Fig. 28: Deviation VEGAFLEX 67 in coax version

1

Dead zone - no measurement possible in this area

L

Probe length

Influence of the ambient temperature to the sensor electronics

T

emperature drift

0.03 %/10 K

relating to the max. measuring range

or max. 0.3 %

T

emperature drift - Digital output

3

mm/10 K relating to the max. measuring range or

max. 10 mm

Ambient conditions

A

mbient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

P

rocess pressure

-1 … +100

bar/-100 … +10000 kPa (-

-14.5 … +1450

psig), depending on the process

tting

P

rocess temperature (thread or flange tem-

perature)

-20 … +250 °C (-4 … +482 °F)

T

he measurement error from the process condi-

tions is in the specified pressure and temperature
range of below 1 %.