VEGA VEGACAP 67 - Relay (DPDT) User Manual
Page 31
31
9 Supplement
VEGACAP 67 • - Relay (DPDT)
31315-EN-130916
2
1
3
200 °C
(292 °F)
300 °C
(572 °F)
100 °C
(212 °F)
400 °C
(752 °F)
0 °C
(32 °F)
-50 °C
(-58 °F)
16 bar
(232psi)
Fig. 33: Process temperature - Process pressure
1 Process temperature
2 Process pressure
3 Temperature range with external housing
Dielectric constant
≥ 1.5
Electromechanical data
Cable entry/plug (dependent on the version)
Ʋ Single chamber housing
– 1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind plug M20 x 1.5; attached 1 x cable entry
M20 x 1.5
or:
– 1 x cable entry ½ NPT, 1 x blind plug ½ NPT, 1 x cable
entry ½ NPT
or:
– 1 x plug M12 x 1; 1 x blind plug M20 x 1.5
Spring-loaded terminals
for wire cross-section up to 1.5 mm² (AWG 16)
Adjustment elements
Mode switch
Ʋ Min.
Min. detection or dry run protection
Ʋ Max.
Max. detection or overflow protection
DIL switch for measuring range selection
Ʋ range 1
0 … 20 pF
Ʋ range 2
0 … 85 pF
Ʋ range 3
0 … 450 pF
Potentiometer
Switching point adaptation
Voltage supply
Operating voltage
20 … 253 V AC, 50/60 Hz, 20 … 72 V DC (at
U >60 V DC, the ambient temperature can be max.
50 °C/122 °F)
Power consumption
1 … 8 VA (AC), approximately 1 W (DC)
Electrical protective measures
Protection rating
IP 66/IP 67
Overvoltage category
III
Protection class
I