beautypg.com

2 mounting, 2mounting – VEGA VEGAFLEX 63 Spacer Cable-ø 4 mm _ Rod-ø 10 mm User Manual

Page 3

background image

2

Mounting

1

Fig. 1: Mounting of the spacer

1

Spacer

1

Measure the diameter of the standpipe or bypass tube and adapt
the spacers accordingly. The markings on the 4-leg spacer ensure
a simple tailoring to the tube diameter DN 50 (2") and DN 80 (3").
For cutting, use a metal saw or strong pliers.

2

With rod version, mount the spacer at the lower edge of the probe
rod. If several spacers are necessary, these should be mounted at
a distance of approx. 2.50 m (8 ft).

With cable version, the spacers must be mounted at a distance of
approx. 1.50 m (5 ft).

3

Place the spacer (1) from the side to the rod or cable of the probe.

The spacer must not be shifted in axial direction. The isolation of the
cable or rod could be damaged. You can remove the spacer laterally
and attach it again in another position.

Spacer • Cable-ø 4 mm / Rod-ø 10 mm

3

2 Mounting

33028

-

EN

-100527