beautypg.com

VEGA VEGAFLEX 66 (-20…+250°C) 4 … 20 mA_HART two-wire User Manual

Page 50

background image

-

2. HART

value (Secondary Value)

D

istance to the level - scaled (for example hl, %)

R

esolution, digital

>

1

mm (0.039 in)

Accuracy (similar to DIN EN 60770-1)

P

rocess reference conditions according to DIN EN 61298-1

-

T

emperature

+

18 … +30 °C (+64 … +86 °F)

-

R

elative humidity

45 … 75 %

-

A

ir pressure

+

860 … +1060

mbar/+86 … +106 kPa

(+12.5 … +15.4

psig)

I

nstallation reference conditions

-

M

in. distance to installations

>

500

mm (19.69 in)

-

V

essel

metallic, ø 1 m (3.281 ft), centric installation,
process fitting flush with the vessel ceiling

-

M

edium

W

ater/Oil (Dk value ~2.0)

-

I

nstallation

P

robe end does not touch the vessel bottom

S

ensor parameter adjustment

G

ating out of false signals carried out

I

n bulk solids applications, implementing a false

signal suppression is generally not recommended.
T

he accuracy of bulk solid applications depends

considerably on the application. Hard and fast
accuracy specifications are thus not available.

D

eviation

see diagrams
D

epending on the installation conditions, there can

be deviations which can be rectified with an
adaptation of the adjustment or a change of the
measured value offset in the DTM service mode.

50

VEGAFLEX

66 • 4 … 20

mA/HART two-wire

10 S

upplement

34169

-EN

-100426