Density - standard – VEGA VEGAVIB 67 - contactless electronic switch User Manual
Page 29
Process conditions
Parameter
Limit level of solids
Process pressure
-1 … 16 bar/-100 … 1600 kPa (-14.5 … 232 psi)
6 bar
(87psi)
-50˚C
(-58˚F)
16 bar
(232psi)
50˚C
(122˚F)
100˚C
(212˚F)
0˚C
(32˚F)
150˚C
(302˚F)
200˚C
(392˚F)
250˚C
(482˚F)
1
2
Fig. 14: Process pressure - Product temperature
1
Product temperature
2
Process pressure
VEGAVIB 67 of 316L
-50 … +150 °C (-58 … +302 °F)
Process temperature (thread or flange
temperature) with temperature adapter
(option)
-50 … +250°C (-58 … +482°F)
1
2
3
-50˚C
(-58˚F)
50˚C
(122˚F)
40˚C
(104˚F)
-40˚C
(-40˚F)
80˚C
(176˚F)
0˚C
(32˚F)
100˚C
(212˚F)
150˚C
(302˚F)
200˚C
(392˚F)
250˚C
(482˚F)
Fig. 15: Ambient temperature - Product temperature
1
Product temperature
2
Ambient temperature
3
Temperature range with temperature adapter
Density
- Standard
Supplement
VEGAVIB 67 - with contactless electronic switch
29
29296
-EN
-060508
- VEGABAR 25 (24 pages)
- VEGAFLEX 55K (32 pages)
- VEGABAR 17 (36 pages)
- D80 Hydrostatic pressure transmitters (40 pages)
- VEGAMET 513 (52 pages)
- D81 Hydrostatic pressure transmitter (44 pages)
- VEGASTAB 690 (12 pages)
- VEGASWING 83 fail safe and signal conditioning instrument VEGATOR 526 Ex (28 pages)
- VEGACONNECT 2 (4 pages)
- D81 METEC Hydrostatic pressure transmitter (44 pages)
- VEGAPULS 45 4 … 20 mA; HART compact sensor (72 pages)
- VEGAMET 515 (68 pages)
- VEGAFLEX 52K (32 pages)
- Capacitive electrodes EK Profibus PA (56 pages)
- VEGATOR 631 S1 (4 pages)
- VEGAPULS 63 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART - two-wire (68 pages)
- Capacitive electrodes EK 4 … 20 mA - Compact (40 pages)
- VEGABAR 65 4 … 20 mA_HART (76 pages)
- VEGABAR 64 Profibus PA (80 pages)
- VEGABAR 44 4 … 20 mA (28 pages)
- VEGADIS 50 Ex (8 pages)
- VEGAPULS 51V…54V (96 pages)
- VEGAFLEX 54P (Profibus PA) (48 pages)
- VEGASEL 643 (16 pages)
- VEGAPULS 56K (68 pages)
- VEGAFLEX 54K (36 pages)
- VEGABAR 41 HART (44 pages)
- VEGATOR 537 Ex (16 pages)
- VEGACAP 82-98 (36 pages)
- VEGADIS 371 Ex (20 pages)
- Capacitive electrodes EL Profibus PA (56 pages)
- VEGAFLEX 52V (36 pages)
- VEGAFLEX 51K (32 pages)
- VEGALOG 571 EP (Ex) (32 pages)
- D84 Hydrostatic pressure transmitter (44 pages)
- VEGABAR 64 Foundation Fieldbus (80 pages)
- VEGABAR 61 4 … 20 mA_HART (80 pages)
- VEGASCAN 850 (92 pages)
- VEGASON 54P…56P Profibus PA (68 pages)
- D77 Hydrostatic pressure transmitters (24 pages)
- VEGATRENN 546 Safety barrier type 146 (8 pages)
- VEGASON 71 - 1 … 75 - 1 (52 pages)
- VEGABAR 40 HART (40 pages)
- Capacitive electrodes EL … (44 pages)
- VEGABAR 24 (28 pages)