Sensor length (L) - suspension cable FEP
(-40 … +150 °C/-40 … +302 °F)
0.6 … 80 m (1.969 … 262.47 ft)
Output variable
Output
Relay output (DPDT), 2 floating spdts
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.
Turn-on voltage
-
Min.
10 mV
-
Max.
253 V AC, 253 V DC
With circuits > 150 V AC/DC, the relay contacts
must be in the same circuit.
Switching current
-
Min.
10 µA
-
Max.
3 A AC, 1 A DC
Breaking capacity
-
Min.
50 mW
-
Max.
750 VA AC, 54 W DC
If inductive loads or stronger currents are switched
through, the gold plating on the relay contact
surface will be permanently damaged. The contact
is then no longer suitable for switching low-level
signal circuits.
Contact material (relay contacts)
AgNi (Au plated) or AgSnO (Au plated)
Modes (switchable)
min./max.
Switching delay
-
When immersed
0.5 s
-
When laid bare
1 s
Ambient conditions
Ambient temperature on the housing
-40 … +80 °C (-40 … +176 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Process conditions
Measured variable
Limit level of solids
Process pressure
-1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psig)
Process temperature with PUR suspension
cable
-20 … +80 °C (-4 … +176 °F)
Process temperature with FEP suspension
cable
-40 … +150 °C (-40 … +302 °F)
Product density
-
Standard
>
0.05 g/cm³ (0.002 lbs/in³)
-
adjustable
>
0.02 g/cm³ (0.0007 lbs/in³)
VEGAVIB
62 • - Relay (DPDT)
25
9 Supplement
29271
-
EN
-120418