beautypg.com

VEGA VEGACAL 66 4 … 20 mA_HART - two-wire User Manual

Page 44

background image

44

10 Supplement

VEGACAL 66 • 4 … 20 mA/HART - two-wire

30036-EN-130917

1000

750

500

250

12

18

16

14

20

22

24

26

28

30

32

34

36

V

4

1

2

3

Fig. 27: Voltage diagram
1 HART load

2 Voltage limit EEx-ia instrument

3 Voltage limit non-Ex/Ex-d instrument

4 Operating voltage

Operating voltage with illuminated display and adjustment module

Ʋ Non-Ex instrument

20 … 36 V DC

Ʋ EEx-ia instrument

20 … 30 V DC

Ʋ EEx-d-ia instrument

20 … 36 V DC

Permissible residual ripple

Ʋ < 100 Hz

U

ss

< 1 V

Ʋ 100 Hz … 10 kHz

U

ss

< 10 mV

Load

see diagram

Electrical protective measures
Protection, depending on housing version

Ʋ Plastic housing

IP 66/IP 67

Ʋ Aluminium housing, stainless steel

housing - investment casting, stain-

less steel housing - electro-polished

IP 66/IP 68 (0.2 bar)

2)

Ʋ Aluminium and stainless housing, in-

vestment casting (optionally available)

IP 66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

Functional safety (SIL)
Functional safety is already activated on instruments with SIL qualification ex factory. On instru-

ments without SIL qualification ex factory, the functional safety must be activated by the user via

the display and adjustment module or via PACTware for applications according to SIL.

Functional safety according to IEC 61508-4

Ʋ Single channel architecture (1oo1D) up to SIL2

2)

A suitable cable is the prerequisite for maintaining the protection rating.