beautypg.com

VEGA VEGACAL 63 4 … 20 mA_HART - two-wire User Manual

Page 23

background image

23

5 Connecting to power supply

VEGACAL 63 • 4 … 20 mA/HART - two-wire

30027-EN-130917

1

2

1 2

Fig. 17: Connection compartment, Ex-d double chamber housing
1 Spring-loaded terminals for power supply and cable screen

2 Ground terminal for connection of the cable screen

1

1

2

Fig. 18: Wiring plan, Ex-d double chamber housing
1 Voltage supply, signal output

5.6 Wiring plan - version IP 66/IP 68, 1 bar

1

2

Fig. 19: Wire assignment, connection cable
1 brown (+) and blue (-) to power supply or to the processing system

2 Shielding

Connection compartment

Wiring plan

Wire assignment, con-

nection cable