beautypg.com

VEGA VEGAVIB 62 - transistor (NPN-PNP) User Manual

Page 27

background image

Electromechanical data - version IP 66/IP 68 (1 bar)

Cable entry

-

Single chamber housing

l

1 x IP 68 cable gland M20 x 1.5; 1 x blind
stopper M20 x 1.5

or:

l

1 x closing cap ½ NPT, 1 x blind plug ½ NPT

Connection cable

-

Wire cross-section

0.5 mm² (AWG 20)

-

Wire resistance

<

0.036 Ω/m (0.011 Ω/ft)

-

Tensile strength

<

1200 N (270 lbf)

-

Standard length

5 m (16.4 ft)

-

Max. length

1000 m (3280 ft)

-

Min. bending radius

25 mm (0.984 in) with 25 °C (77 °F)

-

Diameter approx.

8 mm (0.315 in)

-

Colour - standard PE

Black

-

Colour - standard PUR

Blue

-

Colour - Ex-version

Blue

Adjustment elements

Mode switch

-

Min.

Min. detection or dry run protection

-

Max.

Max. detection or overflow protection

Voltage supply

Operating voltage

10 … 55 V DC

Power consumption

max. 0.5 W

Electrical protective measures

Protection rating

-

Plastic housing

IP

66/IP 67

-

Aluminium and stainless steel standard

IP

66/IP 68 (0.2 bar)

3)

-

Aluminium and stainless housing (op-
tionally available)

IP

66/IP 68 (1 bar)

Overvoltage category

III

Protection class

II

Approvals

Instruments with approvals can have different technical data depending on the version.

3)

A suitable cable is the prerequisite for maintaining the protection rating.

VEGAVIB

62 • - transistor (NPN/PNP)

27

9 Supplement

29273

-

EN

-120418