beautypg.com

VEGA VEGAVIB 63 - contactless electronic switch User Manual

Page 28

background image

Density

-

Standard

>

0.05 g/cm³ (0.002 lbs/in³)

-

adjustable

>

0.02 g/cm³ (0.0007 lbs/in³)

Granular size

no limitation

1)

Electromechanical data

Cable entry/plug (dependent on the version)

-

Single chamber housing

l

1 x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),
1 x blind stopper M20 x 1.5; attached 1 x cable
entry M20 x 1.5

or:

l

1 x cable entry ½ NPT, 1 x blind stopper ½ NPT,
1 x cable entry ½ NPT

or:

l

1 x plug M12 x 1; 1 x blind stopper M20 x 1.5

Spring-loaded terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Adjustment elements

Mode switch

-

Min.

Min. detection or dry run protection

-

Max.

Max. detection or overflow protection

Voltage supply

Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 253 V DC

Domestic current requirement

approximately 3 mA (via load circuit)

Load current

-

Min.

10 mA

-

Max.

400 mA (at I > 300 mA the ambient temperature can
be max. 60 °C/140 °F) max. 4 A up to 40 ms

Electrical protective measures

Protection rating

IP

66/IP 67

Overvoltage category

III

Protection class

I

Approvals

Instruments with approvals can have different technical data depending on the version.

That's why the associated approval documents have to be noted with these instruments. They are
part of the delivery or can be downloaded under www.vega.com via "VEGA T

ools" and "serial

number search" as well as via "Downloads" and "Approvals".

1)

max. 20 mm (0.8 in) with product density < 0.05 g/cm³ (0.002 lbs/in³).

28

VEGAVIB

63 • - contactless electronic switch

9 Supplement

29278

-EN

-120418