Note:
It is recommended to remove the handle after locking the
catch. This protects the ball valve fitting PASVE against
unauthorized access.
4.6 D
ismount pressure transmitter
Danger:
The dismounting of the pressure transmitter must never be
carried out in position "Operation". Medium can escape under
operating pressure and cause damage to property or injury to
persons.
Proceed as follows:
1
Remove cover
2
Attach the handle and unlock the catch by 3½ turns to the
left
3
Hold the ring and bring ball valve with handle into position
"S
ervice", catch snaps in
4
Unscrew the pressure transmitter
5
Turn handle 3½ turns to the right so that the catch is locked
again
The dismounting of the pressure transmitter is hence finished.
The reinstallation is carried out as described in chapter
"M
outing the pressure transmitter".
Danger:
Never bring the ball valve into position "Operation" without
having the pressure transmitter mounted. Medium can escape
and cause damage to property or injury to persons.