It functions even when exposed to strong external vibration or

changing products.
Fault monitoring

The electronics of VEGAVIB 55 continuously monitors the

following criteria:

l

Correct vibrating frequency

l

Line break to the piezo drive

If one of the stated malfunctions is detected or in case of

power failure, the electronics takes on a defined switching

condition, i.e. the relay deenergises (safe condition).

The tuning fork is piezoelectrically energised and vibrates at its

mechanical resonance frequency of approx. 150 Hz. When the

tuning fork is submerged in the product, the vibration

amplitude changes. This change is detected by the integrated

oscillator and converted into a switching command.

VEGAVIB 55 is a compact instrument, i.e. it can be operated

without external evaluation system. The integrated electronics

evaluates the level signal and outputs a switching signal. With

this switching signal, a connected device can be operated

directly (e.g. a warning system, a PLC, a pump etc.).
The data for power supply are stated in chapter "Technical

data" in the "Supplement".

3.3 Operation

VEGAVIB 55 can detect products with a density >0.08 g/cm³

(0.003 lbs/in³).
On the electronics module you will find the following indicating

and adjustment elements:

l

signal lamp for indication of the switching condition (green/

red)

l

Mode switch for selecting the switching condition (min./

max.)

3.4 Storage and transport

Your instrument was protected by packaging during transport.

Its capacity to handle normal loads during transport is assured

by a test according to DIN EN 24180.

Functional principle

Supply

Packaging

8

VEGAVIB 55 - - double relay (DPDT)

Product description

29301

-EN