beautypg.com

VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART two-wire User Manual

Page 60

background image

V

essel pressure - horn antenna

-1 … 40

bar/-100 … 4000 kPa (-14.5 … 580 psi)

V

essel pressure - parabolic antenna

-1 … 6

bar/-100 … 6000 kPa (-14.5 … 870 psi)

V

essel pressure relating to the flange nom-

inal stage

see supplementary instructions manual "Flanges
according to DIN-EN-ASME-JIS
"

V

ibration resistance

6)

-

H

orn antenna

mechanical vibrations with 4 g and 5 … 100 Hz

-

P

arabolic antenna

mechanical vibrations with 1 g and 5 … 100 Hz

Data on rinsing air connection

P

ressure

<

6

bar (87.02 psi)

A

ir quantity see diagram

0,1

0,0

1,0

2,0

3,0

4,0

5,0

6,0

0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0

(bar)

(m

3

/h)

Fig. 42: Air quantity diagram

T

hread

G⅛ A

C

atch

-

with non-Ex

D

ust protection cover of PE

-

with Ex

T

hreaded plug of 316Ti

R

eflux valve - unmounted (as option with non-Ex version, included in the scope of delivery with Ex

version)

-

M

aterial

316T

i

-

S

eal

FKM (V

iton), FFKM (Kalrez 6375)

-

for tube diameter

6

mm

-

opening pressure

0.5

bar (7.252 psi)

-

N

ominal pressure stage

PN

250

6)

T

ested according to the regulations of German Lloyd, GL directive 2.

60

VEGAPULS

62 • 4 … 20

mA/HART two-wire

10 S

upplement

28435

-EN

-090305