beautypg.com

VEGA VEGAPULS 65 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART two-wire User Manual

Page 51

background image

V

essel pressure

-

S

crewed part PVDF

-100 … 300

kPa/-1 … 3 bar (-14.5 … 43.5 psig)

-

S

crewed part and flange 316L

-100 … 1600

kPa/-1 … 16 bar (-14.5 … 232 psig)

P

rocess temperature (measured on the process fitting)

-

P

rocess fitting, thread PVDF

-40 … +130 °C (-40 … +266 °F)

-

O

ther process fittings

-40 … +150 °C (-40 … +302 °F)

V

ibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

7)

Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar

C

able entry/plug

8)

-

S

ingle chamber housing

l

1

x cable gland M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5

or:

l

1

x closing cap M20 x 1.5; 1 x blind stopper

M

20

x 1.5

or:

l

1

x closing cap ½ NPT, 1 x blind plug ½ NPT

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5

-

D

ouble chamber housing

l

1

x cable entry M20 x 1.5 (cable: ø 5 … 9 mm),

1

x blind stopper M20 x 1.5; 1 x blind stopper

M

16

x 1.5 or optionally available with 1 x plug

M

12

x 1 for VEGADIS 61

or:

l

1

x closing cap ½ NPT, 1 x blind stopper

½

NPT, 1

x blind stopper M16 x 1.5 or

optionally 1 x plug M12 x 1 for VEGADIS 61

or:

l

1

x plug (depending on the version), 1 x blind

stopper M20 x 1.5; 1 x blind stopper M16 x 1.5
or optionally available with 1 x plug M12 x 1 for
VEGADIS

61

S

pring-loaded terminals for wire cross-sec-

tion

>

2.5

mm² (AWG 14)

7)

T

ested according to the regulations of German Lloyd, GL directive 2.

8)

D

epending on the version M12 x 1, according to DIN 43650, Harting, 7/

8" FF.

VEGAPULS

65 • 4 … 20

mA/HART two-wire

51

10 S

upplement

28437

-EN

-090305