VEGA VEGATRENN 544 Ex User Manual
Page 6

6
VEGATRENN 544 Ex
Product description
Voltage output
Number
1 output
Function
analogue output of processing results
Range
0/2 … 10 V
Current
max. 1 mA
Resolution
0,05 % of range
Linearity error
0,05 % of range
Temperature error
0,06 %/10 k of range
Fail safe relay
Contact
1 floating spdt
AgNiO and hard gold plated
Turn-on voltage
min. 10 mV DC
max. 250 V AC/DC
Switching current
min. 10
µ
A
max. 3 A AC, 1 A DC
Breaking capacity
max. 500 VA, 54 W
DISBUS-output
Function
digital transmission of processing results and
system informations to VEGADIS 174 or
VEGACOM 557
Connection line
2-wire (screened)
Line length
max. 1000 m
Indicating element
LED in front plate
green on: operating voltage on
red: fault signal
Ambient conditions
Permissible ambient temperature
-20
°
C … +60
°
C
Storage and transport temperature
-40
°
C … +80
°
C
Electrical connection
Multiple plug component
to DIN 41 612, series F, 36-pole triple row d, b, z
(partly equipped)
Carrier BGT 596 (Ex)
connection to appropriate module
Housing type 505
connection to screw terminals (max. 2,5 mm
2
)
Electrical protective measures
Protection
- not mounted
IP 00
- mounted in
carrier BGT 596 Ex.M
front completely equipped: IP 40
upper and lower side: IP 20
wiring side: IP 00
- mounted into housing type 505
- terminal side
IP 20
- housing in general
IP 30
Protection class
II (in housing type 505)
Overvoltage category
II
>>