beautypg.com

English – Best POLAR User Manual

Page 12

background image

12

eN

english

! The appliance must be installed by a qualified person

in compliance with the instructions provided.

!

Wear gloves when carrying out installation and

maintenance operations.

aIr VeNT

(for ducting versions)

! Prepare the hole and the air vent duct (150 mm dia-

meter).

! Use a duct of the minimum indispensible length.

! Use a duct with as few elbows as possible (maximum

elbow angle: 90°).

! Avoid drastic changes in the duct cross-section.

! Use a duct with an as smooth as possible inside.

! The duct must be made of certified material.

! Do not connect the hood to smoke exhaust ducts

for the products of combustion (boilers, fireplaces,

stoves, etc).

! For the air vents comply with the provisions laid down

by the competent authorities.

In addition, the air must not be evacuated through a

hole in the wall unless specifically intended for this

purpose.

! Fit air intakes in the room to prevent the hood from

creating a negative pressure in the room (which must

not exceed 0.04 mbar); if the hood is used at the

same time as non-electrical equipment (gas-, oil- and

charcoal-fired stoves, etc.) the exhaust gas may be

sucked in by the heat source.

FIlTerING or dUcTING VerSIoN ?

The hood may be in filtering or in ducting version. Deci-

de from the outset which type is to be installed.

For better efficiency, we recommend installing the hood

in the ducting version (if possible).

ducting version

The hood purifies the air and evacuates it to the outside

through an exhaust duct (diameter 150 mm).

Filtering version

The hood purifies the air and recycles the clean air

back into the room.

coNTrolS

P1

P2

P3

P4

L1

P

5

P1:

5’ TIMER

P2:

Filter alarm reset

P3:

Motor off / speed decrease – .

- holding down the button, the motor turns off sto-

ring the current speed

P4:

Motor on / speed increase

P5:

Lights on/off

l1

Signalling crown:

-

Hood in standby: lights up amber-orange. 30” after

the last key has been pressed the crown turns off

-

Motor on: L1 lights up turquoise flashing. The

flashing frequency is proportional to the speed

-

5’ TIMer function :

L1 lights up turquoise fixed

-

Filter alarm active:

L1 lights up red fixed (30h); L2

lights up red flashing (120h)

MaINTeNaNce

! Before cleaning or maintenance cut the power.

cleaning the hood

WHEN TO CLEAN IT: clean it at least every 2 months

to prevent the risk of fire.

EXTERNAL CLEANING: use a cloth moistened in luke-

warm water and neutral detergent (for painted hoods);

use specific products for steel, copper or brass hoods.

INTERNAL CLEANING: use a cloth (or brush) soaked

in denatured ethyl alcohol.

WHAT NOT TO DO: do not use abrasive or corrosi-

ve products (e.g. metal sponges, brushes, too hard

brushes, very aggressive detergents, etc.)

Cleaning the grease filters

WHEN TO CLEAN IT: clean it at least every 2 months to

prevent the risk of fire.

HOW TO REMOVE THE FILTERS: push the catch near

the handle towards the rear of the hood and pull the

filter downwards

HOW TO CLEAN THE FILTERS: hand wash or in the

dishwasher using a neutral detergent. If washing in the