background image

English - 5

The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem, contact your service agent.

Warning: Switch off and remove plug from mains before investigating fault.

Fault Finding

Symptom

Possible Cause

Remedy

Machine fails to operate

Power turned off

Mains socket faulty

Extension cable damaged

Fuse faulty/blown

Mower in long grass

Motor protector has activated

Safety cut out has activated

Turn power on

Use another socket

Inspect cable, replace if damaged

Replace fuse

Increase height of cut and tilt mower

Allow to cool for a few minutes and in-
crease height of cut

At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out

Machine functions
intermittently

Extension cable damaged

Machines internal wiring damaged

Motor protector has activated

Safety cut out has activated

Inspect cable, replace if damaged

Contact Service Agent

Allow to cool for a few minutes and in-
crease height of cut

At this time do not operate the switch
lever 1 as this will prolong the reset
time of the safety cut out

Machine leaves ragged
finish
or
motor labours

Height of cut too low

Cutting blade blunt

Underside of machine badly clogged

Blade fitted upside down

Increase height of cut (see “Height of
Cut Adjustment”)

Replace blade
(see “Blade Maintenance”)

Clean machine (see “After Mowing/
Storage”)

Refit blade correctly (see “Blade Main-
tenance”)

Cutting blade not rotating Cutting blade obstructed

Blade nut/bolt loose

Clear obstruction

Tighten blade nut/bolt

Excessive vibration/
noise

Blade nut/bolt loose

Cutting blade damaged

Tighten blade nut/bolt

Replace blade.

F016 L70 451.book Seite 5 Mittwoch, 31. Januar 2007 9:38 09

16 • F016 L70 451 • 07.01