Periodic inspection, A. inspection procedures – ACR&Artex ELT to Nav Interface User Manual
Page 32

ARTEX PRODUCTS / ACR ELECTRONICS, INC.
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
453-6500
25-69-10
Page 32 of 58
APR 30/12
TASK 25-69-10-750-802
2. Periodic Inspection
SUBTASK 25-69-10-220-001
A. Inspection Procedures
(1)
Remove the ELT/NAV Interface in accordance with SUBTASK 25-69-10-050-001, on page 39.
(2)
Perform a visual inspection of the chassis exterior, checking for:
(a)
Damage to the finish,
(b)
Corrosion,
(c)
Excessive wear of the mounting holes, and
(d)
Cracks in the mounting flanges.
(3)
Perform a visual inspection of the mounting hardware for condition and corrosion.
(4)
Perform a visual inspection of the connectors, checking for:
(a)
Corrosion,
(b)
Bent or broken pins, and
(c)
Security of wires in the pins and pins in the connector socket.
NOTE: A slight tug on each wire will reveal a wire loose in the pin (i.e., bad crimp) or
an improperly seated pin in the connector socket.
(5)
Inspect the P2 interface wiring between the ELT/NAV Interface and the ELT for:
(a)
Security,
(b)
Evidence of damage, and
(c)
Evidence of insulation deterioration.
(6)
Inspect the P1 24-bit address wiring between the ELT/NAV Interface and ground or 24-bit
address switch block for:
(a)
Security,
(b)
Damage,
(c)
Insulation deterioration, and
(d)
Grounding points for corrosion.
(7)
Reinstall the ELT/NAV Interface in accordance with SUBTASK 25-69-10-450-002, on page 43.