after 5’ (the pilot lamp flashes). Button C: drives the motor in second speed (the corresponding pilot lamp comes on);
when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops
after 5’ (the pilot lamp flashes). Button D: drives the motor in third speed (the corresponding pilot lamp comes on);
when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops
after 5’ (the pilot lamp flashes). Button E: drives the motor in fourth speed (the corresponding pilot lamp comes on);
when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops
after 5’ (the pilot lamp flashes).

Pay special attention to the grease filters: if the model purchased has the controls shown in Figure 13: the

grease filters must be cleaned approximately once every 30 hours of operation (when the central segment on the
display goes on or starts blinking). To remove the filters: press inward on the clamps at the handles and pull the
filter downward. Wash out the filter using a neutral soap. Once the cleaned filters are reinstalled, keep button R
(Reset) pressed for two seconds to reset the counter. For further information, see the Controls in Fig. 13 in the
paragraph entitled “Operation”. If the model purchased has the controls shown in Figure 11/12: the grease filter must
be cleaned periodically: exactly how often depends on use (at least once every other month). To remove the filter:
push inward on the clamp at the handle and pull the filter downward. Wash out the filter using a neutral soap. If the
model purchased has the controls shown in Figure14: the grease filters must be cleaned approximately once every
30 hours of operation (when the light button lamp comes on) - Fig. 14S). To remove the filters: press inward on the
clamps at the handles and pull the filter downward. Wash out the filter using a neutral soap. Once the cleaned filters
are reinstalled, to reset the counter hold the light button pressed down for about 1” (Fig.14A) while the corresponding
pilot lamp (S) is on. For further information, see the Controls in Fig.14 in the paragraph entitled “Operation”.

Replacing the charcoal filters: for filtering hoods, the charcoal filters must be replaced; remove the filter with

a twisting movement (Fig. 15). If the model purchased has the controls shown in Figure 13, the charcoal filters must
be replaced whenever the central segment of the display starts blinking (i.e. every 120 hours of operation). If the
model purchased has the controls shown in Figure 11/12, the charcoal filters must be replaced according to use:
on the average once every 6 months. If the model purchased has the controls shown in Figure 14, the charcoal filters
must be replaced each time the light button (Fig.14S) lamp flashes (i.e. every 120 hours of operation).

To gain access to the incandescence bulbs, remove the grease filters as described above and remove the

bulbs. Replace with lamps of the same type.

If the halogen lamps need changing, slacken the ring nut in an anticlockwise direction and remove the bulb itself

(Fig. 16). Replace with a bulb of the same type. CAUTION: Do not handle glass bulb with bare hands.

The motor used in this hood features a safety device (thermal cutout) that responds to temperature changes
For accidental reasons or due to installation faults, this device could engage and automatically shut off the
motor, thereby preventing serious damage to the equipment. In such cases, after allowing the motor to cool
down, the hood can be switched on again; the cause of the fault will nonetheless have to be remedied,
ensuring installation has been correctly made and that all the instructions in the Information sheet have been
complied with.

DEUTSCH

GERÄTEAUSFÜHRUNG

Das Gerät kann in Umluftversion und in Abluftversion geliefert werden. In der Umluftversion (Abb. 1) werden

die durch das Gerät geleitete Luft und der Dampf durch Kohlefilter gereinigt und dann über die seitlichen Lüftungsgitter
der Haube wieder in Zirkulation gebracht. ACHTUNG: Bei Verwendung der Umluftversion sind ein Kohlefilter und ein
Luftableitblech (A) notwendig, das in den unteren Teil des Rohrs eingebaut wird und ein erneutes Einleiten der Abluft
in den Raum ermöglicht. Die Kohlefilter werden nicht mitgeliefert. In der Abluftversion (Abb. 2) werden die Dämpfe
und Küchengerüche direkt über eine Evakuationsöfffnung in der Wand oder Decke nach außen abgezogen. Daher
sind keine Kohlefilter notwendig.

MONTAGE DES GERÄTS

Vor den Montageoperationen muß/müssen zur leichteren Handhabung des Geräts die Fettfilter entfernt werden:

Den Festhalter in der Nähe des Griffs nach innen drücken und den Filter nach unten ziehen (Abb. 3).

Befestigung an der Wand (Abb. 4): Benutzen Sie die Bohrschablone, um die Dübel in der Wand anzubringen,

wobei der Abstand zwischen der Haube und dem Kochfeld mindestens 65 cm betragen muß. Nun kann das Gerät
mit den Schlüssellochöffnungen in der Geräterückwand in die Schrauben eingehängt werden (A). Zusätzlich wird das
Gerät durch die Sicherungslöcher fest mit der Wand verschraubt (B). Um das Gerät nicht zu beschädigen, dürfen nur
die vom Hersteller vorgesehenen Bohrungen benutzt werden.

Befestigung der Teleskoprohre: Mindestanforderungen für die Montage: – Stromversorgungsanschluß innerhalb

der Außenabmessungen des Teleksoprohres vornehmen. – Wenn Ihr Gerät als Abluftversion installiert wird, ist ein
Loch zur Abführung der Luft vorzusehen.
Positionieren Sie die Halterung (W) 50 mm von der Decke entfernt, vertikal oberhalb der Haube unter Zuhilfenahme
der Schlitze in der Mitte der Halterung (Abb. 5). Markieren Sie mit einem Filzstift die beiden Bohrlöcher an der Wand.
Führen Sie die Bohrungen aus und stecken Sie die mitgelieferten Dübel in die Bohrlöcher. Befestigen Sie die
Halterung mit den beiden mitgelieferten Schrauben.