beautypg.com

English – TIMBERK Corona series AC TIM...S8 User Manual

Page 7

background image

7

www.timberk.com Electric air conditioner (split system, in set of two units)

Checks before starting:
Make sure that an air filter is installed.
Make sure that air inlet and outlet grilles of the outdoor unit are not
blocked by foreign objects.
Cleaning of air filter
Air filter cleans the air entering the conditioner from dust and foreign
particles. If the filter is contaminated, the conditioner capacity decreases
sharply.
If the conditioner is operated permanently, the filter should be cleaned
once per two weeks.
If the conditioner is installed in a room with dusty atmosphere, then the air
filter should be cleaned more often.
To remove the filter, open the indoor unit panel.
Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean
water. If the filter is contaminated heavily, clean it with a soft brush and
wash in diluted washing solution, then dry it in a cool place.
While cleaning the filter with the vacuum cleaner, hold it with
contaminated surface up. While washing the filter in water, hold it with
contaminated surface down.
Do not dry the filter in the sun or near a fire.
Set the air filter to initial position and close the panel.

9. TROUBLESHOOTING

Failures and their possible reasons:

D_gjs pc

Possible reason

Actions

Interruptions in power supply

Wait for restoration of power supply

Batteries in the remote control board are low

Replace the batteries

The conditioner does not

work

Time of turning on is set by the timer

Wait till the conditioner turns on by
the timer or cancel the timer setting

The set air temperature is too high or too low Set the air temperature correctly
The air filter is clogged with dust

Clean the air filter

Insufficient cooling or

heating capacity

Foreign objects block the air inlet and return
air grillages of the outdoor unit

Remove foreign objects

A three-minute delay of compressor turning
on

Wait a little

The conditioner works, but

does not cool or heat the

room

The air temperature is set incorrectly

Set the temperature correctly

10.SERVICE LIFE
Service life of the appliance is 10 years provided that the respective
installation and operation rules are observed.

Date of the conditioner manufacture is shown in a serial number of the
device. For more details, please, ask a shop assistant.

11. UTILIZATION RULES
Upon expiration of the service life, the appliance should be utilized in
accordance with norms, regulations and procedures effective in the
place of utilization.

ENGLISH