Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
The dust produced when using this tool may be harmful to health
(e.g. when working oak or beech wood, stones, paint, which could
contain lead or other harmful chemicals). Do not inhale the dust.
Use a dust absorption system and wear a suitable dust protection
mask. Remove deposited dust thoroughly, e.g. with a vacuum
cleaner.
Do not use machines on any material containing asbestos.
This machine is suitable only for dry sanding.
SPECIFIED CONDITIONS OF USE
This eccentric sander is a versatile machine. The following work can
be carried out with it: Coarse sanding and grinding, Fine sanding
and polishing, Rubbing down weather-beaten paint, Rubbing down
weather-beaten paint, Polishing up scratches on acrylic glass, Etc.
Do not use this product in any other way as stated for normal use.
WARNING!
WARNING! Read all safety warnings and all instructions,
including those given in the accompanying brochure.
Failure to follow the warnings and instructions may result in
electric shock, fire and/or serious injury. Save all warnings and
instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing loss.
Appliances used at many different locations including open air
should be connected via a residual current device (FI, RCD, PRCD) of
30mA or less.
Always wear goggles when using the machine. It is recommended
to wear gloves, sturdy non slipping shoes and apron.
Only plug-in when machine is switched off.
Always disconnect the plug from the socket before carrying out any
work on the machine.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
TECHNICAL DATA
Random Orbital Sander
ROS 125 E
ROS 150 E-2
Production code
4331 91 01...
4331 81 01...
... 000001-999999
4311 71 01...
4311 81 01...
... 000001-999999
Rated input
300 W
440 W
No-load speed
7000-12000 min
-1
4000-10000 min
-1
Orbital travel diameter-ø
2,4 mm ( 3/32“)
3,0 / 6,0 mm
Dimensions of grinding plate
125 mm
150 mm
Weight according EPTA-Procedure 01/2003
1,7 kg
3,0 kg
Noise/Vibration Information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K=3dB(A))
81,0 dB (A)
83,5 dB (A)
Sound power level (K=3dB(A))
92,0 dB (A)
94,5 dB (A)
Wear ear protectors!
Total vibration values (vector sum in the three axes) determined according to EN 60745.
Vibration emission value a
h
Uncertainty K=
5,0 m/s
2
1,5 m/s
2
6,1 m/s
2
1,5 m/s
2
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given in EN 60745
and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different applications,
with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase the exposure level over
the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or when it is
running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories,