beautypg.com

Microlife MT 16B1 User Manual

Page 2

background image

CLEANING AND DISINFECTING
The thermometer is 100% waterproof and may be immersed
in water or disinfectant solution for cleaning with no problem.
Then wipe it off with a moist towel. Please use one of the
following disinfectants for disinfecting, following the manu-
facturer’s instructions in each case.

й

й˜˜ЛЛТТЪЪНН‡‡ ЛЛ ‰

‰ВВББЛЛММЩ

ÙÂÂÍ͈ˆËËflfl

нВПУПВЪ У·О‡‰‡ВЪ 100 %-МУИ ‚У‰УМВФÓÌˈ‡ВПУТЪ¸˛ Л ПУКВЪ ·ВБ
Н‡НЛı-ОЛ·У ФУ·ОВП ФУ„ЫК‡Ъ¸Тfl ‚ ‚У‰Ы ЛОЛ ‰ÂÁËÌÙˈËЫ˛˘ЛИ
‡ТЪ‚У Т ˆВО¸˛ У˜ЛТЪНЛ. 3‡ЪВП В„У ТОВ‰ЫВЪ ФУЪВВЪ¸ ‚О‡КМУИ
Т‡ОЩВЪНУИ. PÂÍÓÏẨÛÂÚÒfl ‚ ˆÂÎflı ‰ÂÁËÌÙÂ͈ËË ЛТФУО¸БУ‚‡Ъ¸ У‰МУ
ЛБ ФЛ‚В‰ВММ˚ı МЛКВ ‰ÂÁËÌÙˈËÛ˛˘Лı ТВ‰ТЪ‚, ‚ ТУУЪ‚ВЪТЪ‚ЛЛ Т
ЛМТЪÛ͈ËflÏË ФУЛБ‚У‰ËÚÂÎfl ‚ Н‡К‰УП ТОЫ˜‡В

Name of

Manufacturer

Dilution

Max. duration

disinfectant

with water

Method

Isopropyl Immerse

for

alcohol 70%

24 hours

Gigasept FF

Schilke &

5.0%

Immerse for

Mayr GmbH

24 hours

Lysoformin 3000

Rosemann GmbH

6.0%

Immerse for
24 hours

Aseptisol

Bode Chemie

4.0%

Immerse for
24 hours

Note: Any other cleaning solution, dilution or cleaning
method can cause a malfunction of the thermometer!
BATTERY EXHAUSTION
When the «

▼» symbol (upside-down triangle) appears in the

lower right of the display, the battery is exhausted and ther-
mometer needs to be replaced. For battery disposal please
refer to «safety instructions».

З

ЗММЛЛП

П‡‡ММЛЛВВ:: аТФУО¸БУ‚‡МЛВ О˛·У„У ‰Ы„У„У У˜Л˘‡˛˘В„У ‡ТЪ‚У‡

ПУКВЪ ФУ‚ОВ˜¸ Б‡ ТУ·УИ М‡Ы¯ВМЛВ ÙÛÌ͈ËË ЪВПУПВЪ‡.
Истечение срока действия батареи
Появление в правом нижнем углу дисплея символa «

▼» означает, что

батарея исчерпала свой ресурс и термометр нуждается в замене. По
вопросам утилизации батареи см. «Инструкции по безопасности».

н

н≈

≈’

’Х

Х»

»◊

◊≈

≈—

—K

»≈

≈ ’

’∞

∞–

–∞

∞K

K“

“≈

≈–

–»

»—

—“

“»

»K

»

нВПУПВЪ П‡НТЛП‡О¸М˚ı ФУН‡Б‡МЛИ

32,0 °л - 42,9 °л
ЪВПФ.

<

32,0 °л ‰ЛТФОВИ «L» (ТОЛ¯НУП МЛБН‡fl ЪВПФВ‡ЪЫ‡)

ЪВПФ.

>

42,9 °л ‰ЛТФОВИ «H» (ТОЛ¯НУП ‚˚ТУН‡fl ЪВПФВ‡ЪЫ‡)

±

0,1 °л ‚ ‰Л‡Ф‡БУМВ УЪ 34 °л ‰У 42 °л

10 °C ‰Ó 40 °C
П‡НТЛП‡О¸М‡fl УЪМУТЛЪВО¸М‡fl ‚О‡КМУТЪ¸ 15 - 95 %

Д‚ЪУП‡ЪЛ˜ВТНЛИ ‚МЫЪВММЛИ ÙÛÌ͈ËÓÌ‡О¸М˚И ЪВТЪ ФЛ НУМЪУО¸МУП
ФУН‡Б‡ЪВОВ 37,0 °л. иЛ УЪНОУМВМЛЛ ·УОВВ 0,1 °л УЪУ·‡К‡ÂÚÒfl
ФУН‡Б‡МЛВ

«ERR»

(У¯Л·Н‡).

ΔЛ‰НУНЛТЪ‡ООЛ˜ВТНЛИ ‰ЛТФОВИ (LCD)

Ò 3 ˆËÙaПЛ. еЛМЛП‡О¸М‡ˇ

‚ВОЛ˜ЛМ‡ УЪУ·‡ÊÂÌËfl: 0,1 °ë

ÑÎfl ı‡ÌÂÌËfl ФУТОВ‰МВ„У ЛБПВЛЪВО¸МУ„У ФУН‡Б‡МЛfl

УЪ -25 °л ‰У +60 °л
П‡НТЛП‡О¸М‡fl УЪМУТЛЪВО¸М‡fl ‚О‡КМУТЪ¸ 15 - 95 %

1.5 / 1.55 V; SR 41

EN 12470-3,

ωˈËÌÒÍË ЪВПУПВЪ˚;

ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC)

Type / н

нЛ

ЛФ

Ф:

Measurement range /
С

СЛ

Л‡

‡Ф

Ф‡

‡ББУ

УМ

М Л

ЛББП

ПВ

В

В

ВМ

МЛ

ЛИ

И::

Measurement accuracy /
н

нУ

У˜

˜М

МУ

УТТЪЪ¸¸ Л

ЛББП

ПВ

В

В

ВМ

МЛ

ЛИ

И:

Operating temperature /
С

СЛЛ‡‡ФФ‡‡ББУУММ ‡‡··УУ˜˜ËËıı ЪЪВВП

ПФФВВ‡‡ЪЪЫЫ::

Self-test / л

л‡

‡П

ПУ

УН

НУ

УМ

МЪЪ

У

УО

О¸¸:

Display / С

СЛ

ЛТТФ

ФО

ОВ

ВИ

И:

Memory / и

и‡

‡П

Пfl

flЪЪ¸¸:

Storage temperature /
н

нВ

ВП

ПФ

ФВ

В

‡

‡ЪЪЫЫ

‡

‡ ıı

‡

‡М

МВ

ВМ

МЛ

Лfl

:

Battery / ±

±‡

‡ЪЪ‡

‡

В

Вfl

:

Reference to standards /
л

лТТ˚

˚О

ОН

Н‡

‡ М

М‡

‡ ТТЪЪ‡

‡М

М‰

‰‡

‡

ЪЪ˚

˚::

TECHNICAL SPECIFICATIONS

Maximum thermometer

32.0 °C to 42.9 °C
Temp. < 32.0 °C: display «L» for low (too low)
Temp. > 42.9 °C: display «H» for high (too high)

± 0.1 °C between 34 °C and 42 °C

10 °C to 40 °C
15 - 95 % relative maximum humidity

Automatic internal check at a test value of 37 °C;
if there is a deviation of > 0.1°C, «ERR» (error) is displayed.

Liquid crystal display (LCD) with 3 digits
Smallest unit of display: 0.1 °C

For storing the last measured value.

–25 °C to +60 °C
15 - 95 % relative maximum humidity

1.5 / 1.55 V; SR 41

EN 12470-3, clinical thermometers;
ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC)

Technical alterations reserved.
Guarantee
We grant you 2 year guarantee after the date of purchase. Any
damage caused by improper handling shall not be covered by
the guarantee. Batteries and packaging are also excluded from
the guarantee. All other damage claims excluded. A guarantee
claim must be submitted within the warranty period. Please
package your defective thermometer well and send with suffi-
cient postage.
Date of purchase:

Read the instructions carefully before using this device.

Перед использованием прибора внимательно прочтите данное
руководство.

Type BF applied part

дО‡ТТ Б‡˘ЛЪ˚ BF

Made in P.R.C.

и‡‚У М‡ ‚МВТВМЛВ ÚÂıÌ˘ÂÒÍËı ЛБПВМВМЛИ ТУı‡ÌflÂÚÒfl.
Éɇ‡‡‡ÌÌÚÚËËflfl
е˚ ФВ‰УТЪ‡‚ÎflÂÏ ‚‡П „‡‡МЪЛ˛ 2 „У‰‡ Т ПУПВМЪ‡ ФЛУ·ÂÚÂÌËfl
ЪВПУПВЪ‡. С‡ММ‡fl „‡‡ÌÚËfl МВ ‡ТФУТЪ‡ÌflÂÚÒfl М‡ О˛·˚В ФУ‚-
ВК‰ÂÌËfl, ‚˚Б‚‡ММ˚В МВФ‡‚ЛО¸МУИ ˝НТФОЫ‡Ъ‡ˆËÂÈ ФЛ·У‡. ¡‡Ъ‡ВЛ
Л ЫФ‡НУ‚Н‡ Ъ‡НКВ ЛТНО˛˜ВМ˚ ЛБ ‰‡ММУИ „‡‡МЪЛЛ. ЗТВ ЛМ˚В ФВЪВМБЛЛ
М‡ ‚УБПВ˘ВМЛВ Ы˘В·‡ ЛТНО˛˜‡˛ЪТfl. Й‡‡МЪЛИМ‡fl ÔÂÚÂÌÁËfl ‰УОКМ‡
·˚Ъ¸ УЩУПОВМ‡ ТУУЪ‚ВЪТЪ‚Ы˛˘ЛП У·‡БУП. иЛ ‚УБМЛНМУ‚ВМЛЛ
ФВЪВМБЛЛ У·‡ЪЛЪВТ¸ ‚ ‡‰ВТ ТВ‚ЛТМУИ ТОЫК·˚. е˚ ФВ‰УТЪ‡‚ÎflÂÏ
·ВТФО‡ЪМУВ ТВ‚ЛТМУВ У·ТОЫКЛ‚‡МЛВ ‚ ЪВ˜ВМЛВ 10 ОВЪ Т ПУПВМЪ‡
ФЛУ·ÂÚÂÌËfl ЪВПУПВЪ‡.
С‡Ъ‡ ФЛУ·ÂÚÂÌËfl:

С

С

ÂÁËÌÙˈËÛ˛-

П

УЛБ‚У‰ЛЪВО

¸¸

BУ‰М˚И

MÂÚÓ‰

˘ЛВ ТВ‰ТЪ‚‡

‡ТЪ‚У

лФЛЪ ˝ЪЛОУ‚˚И ‰Оfl

иУ„ЫКВМЛВ

М‡ЫКМУ„У ФËÏÂÌÂÌËfl

М‡ 24 ˜‡Т‡

ЙЛ„‡ТВФЪ FF

Schilke &

5,0%

иУ„ЫКВМЛВ

Mayr GmbH

М‡ 24 ˜‡Т‡

гЛБУЩУПЛМ

Rosemann GmbH

6,0%

иУ„ЫКВМЛВ М‡

ТУ‰‡

24 ˜‡Т‡

ДТВФЪЛТУО

Bode Chemie

4,0%

иУ„ЫКВМЛВ
М‡ 24 ˜‡Т‡