3Com 3CNJPSE24 User Manual
Page 23

Appendix A — Safety Information
Ethernet Power Supply User s Guide
A-3
§
Installation and removal of the Ethernet Power Supply must
be carried out by qualified personnel only.
§
Power Cord Set:
The power cord must be approved for the country in which
it is used:
U.S.A. and
Canada
§
The cord set must be UL-
approved and CSA certified.
§
The minimum specification for
the flexible cord is:
No. 18 AWG
Type SV or SJ
3-conductor
§
The cord set must have a rated
current capacity of at least 10A.
§
The attachment plug must be
an earth-grounding type with a
NEMA 5-15P (15A, 125V) or
NEMA 6-15P (15A, 250V)
configuration.
Denmark
§
The supply plug must comply
with section 107-2-D1, standard
DK2-1a or DK2-5a.
Switzerland
§
The supply plug must comply
with SEV/ASE 1011.