beautypg.com

Drive the digital output, Query status of the digital input – 4XEM Network Camera User Manual

Page 79

background image




- 75 -


Drive the digital output

Note: This request requires the privilege of I/O access control.
Method: GET/POST

Syntax:
http://<servername>/cgi-bin/setdo.cgi?do1=[&do2=]
[&do3=][&do4=][&return=]

Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents
on the server type.

parameter Value

description
H – NC connected with COMMON

do

L – NO connected with COMMON

return

Redirect to the page after the
parameter is assigned. The can
be a full URL path or relative path according the
the current path. If you omit this parameter, it
will redirect to an empty page.


Example: Drive the digital output 1 to high and redirect to an empty page

http://myserver/cgi-bin/setdo.cgi?do1=H

Query status of the digital input

Note: This request requires the privilege of I/O access control.
Method: GET/POST