1. FITTING STOVES

Most stoves are heavy and do not require anchoring to the

hearth or floor, but in certain circumstances the appliance

can become unstable e.g. when leaning on the stove. If this is

likely, secure the appliance to the hearth or floor with

suitably strong fixings.

FOR MARLBOROUGH, MANHATTAN, STOCKTON &

STOCKTON 5:

1.1 Position the stove ensuring all appropriate clearances are

observed.

1.2 Mark the position of the holes in the fixing brackets

attached to the inside of the rear legs.

1.3 Remove the stove and drill holes using an appropriate

drill.

1.4 Push rawl plugs into the holes and insert the wood

screws until the head is approximately 3mm proud of the

hearth.

1.5 Place the stove in position over the brackets so that the

screw heads locate in the large part of the slot.

1.6 Push the stove back so that the screw heads engage fully

into the narrow part of the slot.

1.7 Tighten the screws if desired.

2. FAULT FINDING

No illumination of the loose fuels or uneven lighting:

2.1 Check the heater is working. If YES, one or more of the

LED boards will need replacing. This must be undertaken

by a suitably qualified person (see Servicing

Requirements).

2.2 If NO, first change the 13amp fuse for one known to

work. If the fire still does not work, check the socket by

plugging in a working appliance. If this too fails to

operate, call in a competent electrician to check the

socket.

Illumination but no heat

:

2.3 The safety cut-out has operated to protect against

overheating (see User Instructions, Section 2.6). Ensure

the air inlet and outlet grilles are free of dust or any other

obstruction.

Remote control fails to work

:

2.4 Check that the batteries are new and correctly fitted.

Replace if necessary.

2.5 Ensure that the handset is pointed at the window of the

fire.

8

INSTALLATION INSTRUCTIONS

3. HOw TO wIRE A PLUG

If you need to change the plug supplied with this fire,

follow the instructions below. The instructions assume that

the wire has been cut.

wARNING – FAILURE TO CONNECT THE wIRES

CORRECTLY COULD PUT PEOPLE AT RISK FROM

ELECTRIC SHOCK OR FIRE. IF IN DOUBT CONSULT A

QUALIFIED ELECTRICIAN.

UK PLUG

- Suitable for use in Cyprus, Malta, Ireland &

Great Britain

Earth wire

Neutral wire

Outer Insulation

Fuse

Cable grip

3

UK Plug Supplied

Type 33

Live wire

Live Wire

Brown

Terminal L / RED

Neutral Wire

Blue

Terminal N / BLACK

Earth Wire

Green & Yellow

Stripes

Terminal E /

/ GREEN or

GREEN & YELLOW

THIS APPLIANCE MUST BE EARTHED