Maintenance and servicing, Removal of the log guard, Fitting and removal of baffle – Yeoman YM-CL8HB User Manual
Page 33: Fitting a new door glass
33
2. REMOVAL OF THE LOG GUARD
2.1 To remove the Log guard:
—
Lift Log Guard clear of the supporting brackets.
—
Rotate to clear the sides of the door opening.
Do not use appliance without the log guard in position.
3. FITTING AND REMOVAL OF BAFFLE
4.1 See Installation Instructions, Section 3.
4.2 It is important to remove and clean the Baffle system to
ensure the flue ways are clear of soot and debris and to
ensure the safe and efficient operation of the stove. The
frequency of cleaning depends on the stove operating
conditions.
4.3 The baffle system is designed to give safe and efficient
operation of the stove. Replace any damaged baffle
immediately.
4.4 Do not modify the baffle system.
5. FITTING A NEW DOOR GLASS
5.1 To maintain safe use of the appliance damaged door glass
must be replaced immediately. To do this:
—
Open door and lift free of hinge blocks.
—
Lay door face down on a soft flat surface to protect the
paintwork and glass.
—
Remove the glass clamp and screws x 8. The old
glass can then be lifted clear of the door. Note how the
sealing rope is placed around the glass.
Dispose of the old glass safely.
MAINTENANCE and SERVICING
Fixing Screws x 8
Door
PR8738
Glass rope
seal
B
Seal
Length (mm)
Glass rope seal A
1220
Glass rope seal B
460
PR8739
Glass rope
seal
B
Black face
PR8757
Glass rope seal
A
Glass rope
seal