SITE REQUIREMENTS

8

Additional information covering the installation of the

Elegance stove may be found in the British Standard:

BS8303.

HEARTH DIMENSIONS

The appliance must stand on a constructional hearth

with the minimum dimensions as shown in diagram

below.

If you are fitting the appliance into an existing hearth

setting, check that it complies with the current

construction regulations and is at least the minimum sizes

shown.

If you have no existing fireplace or chimney, it is possible

to construct a suitable non-combustible housing and

hearth setting. However this should be constructed to

comply with the requirements of both current national

and local regulations with the design approved by your

local building control officer. Masonry chimney systems

built with clay or concrete liners or pre-fabricated block

systems should be constructed in accordance with BS

6461 : Part 1. Factory made insulated systems should

comply with BS 4543 : Part 2 and be installed to BS 7566

: Parts 1 to 4.

Remember that any new chimney added to your property

may also require planning permission.

WALLS ADJACENT TO HEARTHS

Location of hearth

or Elegance Stove

Where the hearth

abuts a wall and the

Elegance Stove is

not more than

50mm from the

wall

Where the hearth

abuts a wall and the

Elegance Stove is

more than 50mm

but not more than

300mm from the

wall

Where the hearth

does not abut a wall

and is no more

than 150mm from

the wall

Thickness (W)

200mm

75mm

75mm

Height (A)

At least 300mm

above the

Elegance Stove

and 1200mm

above the hearth

At least 300mm

above the

Elegance Stove

and 1200mm

above the hearth

At least 300mm

above the hearth

Solid, non-combustible material

Note: there is no requirement for protection of

the wall where C is more than 150mm

Yeoman Elegance

Wall Thickness W

Solid, non combustable

material e.g concrete or

masonry

150mm

minimum

150mm

minimum

A

C

C

150mm minimum

Constructional

hearth 840mm

minimum

Constructional

hearth 840mm

minimum

Change in level to

mark safe perimeter

225mm

minimum

150mm

minimum

150mm minimum