beautypg.com

Flushing power unit, Maintenance – Yamaha LF225 User Manual

Page 60

background image

Maintenance

54

Batteries vary among manufacturers. There-
fore the following procedures may not always
apply. Consult your battery manufacturer’s in-
structions.
Procedure
1.

Disconnect and remove the battery from
the boat. Always disconnect the black
negative cable first to prevent the risk of
shorting.

2.

Clean the battery casing and terminals.
Fill each cell to the upper level with dis-
tilled water.

3.

Store the battery on a level surface in a
cool, dry, well-ventilated place out of di-
rect sunlight.

4.

Once a month, check the specific gravity
of the electrolyte and recharge as re-
quired to prolong battery life.

EMU28442

Flushing power unit

Perform this procedure right after operation
for the most thorough flushing.

CAUTION:

ECM01530

Do not perform this procedure while the
engine is running. The water pump may be
damaged and severe damage from over-
heating can result.

1.

After shutting off the engine, unscrew the
garden hose connector from the fitting on
the bottom cowling.

2.

Screw the garden hose adapter onto a
garden hose, which is connected to a
fresh water supply, and then connect it to
the garden hose connector.

3.

With the engine off, turn on the water tap
and let the water flush through the cool-
ing passages for about 15 minutes. Turn
off the water and disconnect the garden
hose adapter from the garden hose con-
nector.

4.

Reinstall the garden hose connector onto
the fitting on the bottom cowling. Tighten
the connector securely.

CAUTION:

ECM00540

Do not leave the garden hose connector
loose on the bottom cowling fitting or let
the hose hang free during normal opera-
tion. Water will leak out of the connector

1. Fitting
2. Garden hose connector

3. Garden hose adapter

U69J17E0.book Page 54 Tuesday, March 7, 2006 10:00 AM

This manual is related to the following products: