25

LEVELLING FEET

PENCIL LINE ON THE FLOOR

PLAN VIEW OF THE COOKER

480 mm.

100 mm.

300 mm.

295 mm.

WALL FACE

A

BACK OF COOKER

SIDE VIEW

OF THE COOKER

BASE OF COOKER

ENGAGEMENT EDGE FOR
STABILITY BRACKET

Fig. 3

Fitting the Stability Bracket
(Not supplied)

If the cooker has to be installed with a flexible
supply pipe, it is necessary that a stability device is
fitted.
(See safety Requirements: Page 23).

If a stability bracket should be fitted by the installer,
these instructions should be read in conjunction with
the leaflet packed with the stability bracket.

Place cooker in its intended position and level
cooker.

Mark off 295mm (11

1

/

2

") from the right hand side of

the cooker as shown, this is the centre line of the
bracket fixing.

Draw a line 100mm (4") from the front edge of the
levelling feet (see Fig. 17) and remove cooker from
its position. Mark off 480mm (19") back from this
line on the centre line of the bracket to locate the
front edge of the lower bracket.

Fix lower bracket (with two fixing holes) to the floor,
then measure height from floor level to engagement
edge on back of cooker, dimension 'A' of Fig. 2.

Assemble upper bracket to lower bracket so that
underside of bracket is dimension 'A' +3mm (1/8")
above floor level. Re-position cooker and check that
top bracket engages into cooker back to a depth of
75mm (3"), as shown in Fig. 2.

Should the stability bracket currently installed not
allow the cooker to stand correctly, ask the installer
to replace it with the correct type.

Fig. 2

Connecting to Gas

This cooker is designed to be installed with an
appliance flexible connection. Connection is made to
the RC 1/2 (1/2" B.S.P.) threaded entry pipe located
just below the hotplate level on the rear right-hand
side of the cooker. Check for gas soundness after
connecting the gas supply.

The gas bayonet connector must be fitted in the
shaded area indicated in Fig. 3. Take into account
that it must be possible to pull the cooker forward
sufficiently. The hose must not get caught on the
stability bracket.

Note:

If using different types of gas bayonet connection, it
may not be possible for the appliance to be pushed
fully back to the wall stops.

Important:

Flexible tubing MUST comply with BS.669 Current
Edition.