beautypg.com

Rear panel, Hs80m, hs50m, English – Yamaha HS 50M User Manual

Page 12: Hs50m hs80m

background image

English

12

HS80M/HS50M/HS10W Owner’s Manual

Rear Panel

HS80M, HS50M

1

POWER switch

Turns power to the speaker on or off. When the power is
turned on the tuning fork mark on the front panel will light.

"

LEVEL control

Adjusts the overall output level.

#

INPUT 1/2 connector

These are balanced XLR-type and phone type input
connectors.

Do NOT use both the XLR and Phone type connector at the same
time. Please connect to only one of these connectors.

$

MID EQ switch

Adjusts the level of the mid-frequency range. Setting the
switch to the “0” position produces a flat frequency response.
With the “+2 dB” setting, the mid range is boosted by 2 dB.
With the “-2 dB” setting, the mid range is cut by -2 dB.
(Center frequency is 2 kHz.)

%

ROOM CONTROL switch

Corrects the low frequency exaggeration caused by reflecting
off ceilings, walls and floors. Setting the switch to the “0”
position produces a flat frequency response. With the “-2 dB”
setting, the range below 500 Hz is cut by 2 dB. With the “-4
dB” setting, the range below 500 Hz is cut by -4 dB.

&

HIGH TRIM switch

Adjusts the level of high-frequency range.

HS50M:

Setting the switch to the “0” position produces a flat
frequency response.
With the “+2 dB” setting, the range above 3 kHz is
boosted by 2 dB. With the “-2 dB” setting, the
range above 3 kHz is cut by -2 dB.

HS80M:

Setting the switch to the “0” position produces a flat
frequency response.
With the “+2 dB” setting, the range above 2 kHz is
boosted by 2 dB. With the “-2 dB” setting, the
range above 2 kHz is cut by -2 dB.

'

LOW CUT switch

Cuts the low-frequency range. With the “80 Hz” setting the
range below 80 Hz is cut. With the “100 Hz” setting the range
below 100 Hz is cut.

(

AC IN Connector

Connect the supplied power cable here. First connect the
power cord to the speaker, then insert the power cord plug
into the AC outlet.

ROOM CONTROL

HIGH TRIM

+2dB

+2dB

0dB

0dB

-2dB

-2dB

0dB

-2dB
-4dB

+2dB

0

-2dB

0

-2dB

-4dB

+2dB

0

-2dB

-10dB

+4dB

1

2

MID EQ

ROOM

CONTROL

HIGH

TRIM

LOW CUT

FLAT

80Hz

100Hz

MID EQ

LOW CUT

OFF

INPUT

LEVEL

POWER

ON

AC IN

2kHz

3kHz

500Hz

100Hz

80Hz

FLAT

MIN

+2dB

+2dB

0dB

0dB

-2dB

-2dB

0dB

-2dB
-4dB

2kHz

2kHz

500Hz

100Hz

FLAT

80Hz

ROOM CONTROL

HIGH TRIM

MID EQ

LOW CUT

HS50M

HS80M

!

"

#

$

%

&

'

(

This manual is related to the following products: